Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Avaliação do comprimento e área do corpo caloso fetal por meio da ultrassonografia tridimensional Assessment of length and area of corpus callosum by three-dimensional ultrasonography

Milena Visentainer et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2010

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.
Publicación seriada

A FEBRASGO e o Novo Ano

Esta publicación seriada contiene 195 contenidos relacionados.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

DOAJ DOAJ Articles
Entrar por DOAJ
Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

OBJETIVO: determinar os valores de referência para o comprimento e a área do corpo caloso fetal entre a 20ª e 33ª semanas de gestação por meio da ultrassonografia tridimensional (US3D). MÉTODOS: foi realizado um estudo do tipo corte transversal com 70 gestantes normais entre a 20ª e 33ª semanas de gestação. Utilizou-se um aparelho da marca Accuvix XQ, equipado com transdutor convexo volumétrico (3 a 5 MHz). Para a obtenção do corpo caloso fetal, foi utilizado um plano transfrontal, com a sutura metópica como janela acústica. Para o cálculo do comprimento, utilizou-se a distância entre os pontos médios dos polos proximal e distal do corpo caloso. Para o cálculo da área, a delimitação manual da superfície externa do corpo caloso foi realizada. Para o comprimento e a área do corpo caloso, foram calculadas: as médias, as medianas, os desvios padrão e os valores máximo e mínimo. Para a correlação da área e do comprimento do corpo caloso com a idade gestacional e o diâmetro biparietal foram criados diagramas de dispersão, sendo a qualidade dos ajustes verificada pelo coeficiente de determinação (R²). Para a variabilidade intraobservador, utilizou-se o coeficiente de correlação intraclasse (CCI). RESULTADOS: a média do comprimento do corpo caloso variou de 21,7 mm (18,6 - 25,2 mm) a 38,7 mm (32,6 - 43,3 mm) entre a 20ªe 33ª semanas, respectivamente. A média da área do corpo caloso variou de 55,2 mm² (41,0 - 80,0 mm²) a 142,2 mm² (114,0 - 160,0 mm²) entre a 20ªe 33ª semanas, respectivamente. O comprimento e a área do corpo caloso foram fortemente correlacionados com a idade gestacional (R² = 0,7 e 0,7, respectivamente) e com o diâmetro biparietal (R² = 0,7 e 0,6, respectivamente). A variabilidade intraobservador foi adequada com CCI = 0,9 e 0,9 para o comprimento e área, respectivamente. CONCLUSÕES: valores de referência para o comprimento e área do corpo caloso fetal entre a 20ªe 33ª semanas foram determinados. A variabilidade intraobservador foi adequada.<br>PURPOSE: to establish reference values for the length and area of the fetal corpus callosum between the 20th and 33rd weeks of gestation using three-dimensional ultrasound (3DUS). METHODS: this cross-sectional study involved 70 normal pregnancies with gestational age between 20 and 33 weeks. An Accuvix XQ instrument with a convex volumetric transducer (3 to 5 MHz) was used. To assess the corpus callosum, a transfrontal plane was obtained using the metopic suture as an acoustic window. Length was obtained by measuring the distance between the proximal and distal extremities of the corpus callosum. Area was obtained by manual tracing of the external corpus callosum surface. The means, medians, standard deviations, and maximum and minimum values were calculated for the corpus callosum length and area. Scatter graphs were created to analyze the correlation between corpus callosum length and area and gestational age and biparietal diameter, the quality adjustments was verified according to the determination coefficient (R²). The intraclass correlation coefficient (ICC) was used to assess the intraobserver variability. RESULTS: mean corpus callosum length increased from 21.7 (18.6 - 25.2 mm) to 38.7 mm (32.6 - 43.3 mm) between 20 and 33 weeks of pregnancy, respectively. Mean corpus callosum area increased from 55.2 (41.0 - 80.0 mm²) to 142.2 mm² (114.0 - 160.0 mm²), between 20 to 33 weeks of pregnancy, respectively. There was a strong correlation between corpus callosum length and area and gestational age (R² = 0.7 and 0.7, respectively) and biparietal diameter (R² = 0.7 and 0.6, respectively). Intraobserver variability was appropriate, with an ICC of 0.9 and 0.9 for length and area, respectively. CONCLUSIONS: reference values for corpus callosum length and area were established for fetuses between 20 and 33 weeks gestation. Intraobserver variability was appropriate.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. V. E. (2010). Avaliação do comprimento e área do corpo caloso fetal por meio da ultrassonografia tridimensional Assessment of length and area of corpus callosum by three-dimensional ultrasonography. https://doi.org/10.1590/S0100-72032010001200002

MLA

al, Milena Visentainer et. "Avaliação do comprimento e área do corpo caloso fetal por meio da ultrassonografia tridimensional Assessment of length and area of corpus callosum by three-dimensional ultrasonography." 2010. https://doi.org/10.1590/S0100-72032010001200002.

Chicago

al, Milena Visentainer et. 2010. "Avaliação do comprimento e área do corpo caloso fetal por meio da ultrassonografia tridimensional Assessment of length and area of corpus callosum by three-dimensional ultrasonography.". https://doi.org/10.1590/S0100-72032010001200002.

Harvard

al, M. V. E. 2010, Avaliação do comprimento e área do corpo caloso fetal por meio da ultrassonografia tridimensional Assessment of length and area of corpus callosum by three-dimensional ultrasonography, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032010001200002 [Accessed 5 Aug. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Avaliação do comprimento e área do corpo caloso fetal por meio da ultrassonografia tridimensional Assessment of length and area of corpus callosum by three-dimensional ultrasonography
Autor / colaboradores
Milena Visentainer et al
Editorial
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Año de publicación
2010
ISSN
0100-7203
ISSN
0100-7203
Idioma
Inglés

Materias

Explorá otros recursos relacionados a partir de estas materias.

Copiado