Volver a resultados
Ficha bibliográfica · Consulta y acceso
Artículo

Evaluation of power output through masseter muscle potential measurement in low temperature environments

Kaho Ishikawa et al · Society for Science and Technology · 2021

Material complementario disponible
Lectura rápida. Revisá los datos básicos del recurso y luego accedé al contenido desde el botón principal. En esta ficha solo se muestra la información necesaria para identificar la obra, citarla y abrirla.

Acceso al recurso

Entrá al contenido desde la opción principal o elegí otra fuente disponible.

DOAJ DOAJ Articles
Entrar por DOAJ
Acceso principal

Material complementario disponible

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Abrir material

Resumen

Descripción general del contenido del recurso.

Due to a decline in the productive-age population in Japan, the shortage of human resources in the field of nursing-care have been severe. As a measure for this problem, it is necessary to maintain the quality of nursing-care services by utilizing welfare equipments. Analysing this background, the authors developed a pointing device that controlled by voluntary head movement. However, this device malfunctions in low temperature environments. The factor is the increase in electrical noise due to the decrease in environmental temperature. Therefore, in order to improve the noise resistance of electromyography sampling, bipolar induction was adopted as the method of detecting electromyography. Furthermore, in order to accurately judge the occlusion even with electromyography containing noise, the function to detect multiple clicks was equipped with the pointing device. In this study, first, the operation was tested in low temperature environments (1-5 ℃), middle temperature environments (9-13 ℃) and warm temperature environments (23-24 ℃). Next, the operation reliability influenced by environmental temperature was evaluated based on task success rate and required times. As a result, the task success rate was 95% or more regardless of the environmental temperature, and the required times was about 0.5 sec. In addition, the superimposition of electrical noise or malfunction was not confirmed. On the other hand, some participants commented that their jaws were tired and that they were not suitable for long-term operation, regardless of the environmental temperature. The reason is that the operation of the FPD required more force than the occlusion used in daily life. For this reason, it is indispensable to verify the relationship between the occlusal force and the fatigue of jaw and improve the usability of this device.

Cómo citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, K. I. E. (2021). Evaluation of power output through masseter muscle potential measurement in low temperature environments. https://doi.org/10.11425/sst.10.131

MLA

al, Kaho Ishikawa et. "Evaluation of power output through masseter muscle potential measurement in low temperature environments." 2021. https://doi.org/10.11425/sst.10.131.

Chicago

al, Kaho Ishikawa et. 2021. "Evaluation of power output through masseter muscle potential measurement in low temperature environments.". https://doi.org/10.11425/sst.10.131.

Harvard

al, K. I. E. 2021, Evaluation of power output through masseter muscle potential measurement in low temperature environments, Society for Science and Technology, available at: https://doi.org/10.11425/sst.10.131 [Accessed 5 Aug. 2026].

Compartir e imprimir

Guardá la ficha, copiá su enlace permanente o imprimila como PDF.

Exportar referencia

Si usás un gestor bibliográfico, podés exportar el registro en los formatos más comunes.

Detalles del recurso

Información bibliográfica útil para confirmar que se trata del material correcto.

Título
Evaluation of power output through masseter muscle potential measurement in low temperature environments
Autor / colaboradores
Kaho Ishikawa et al
Editorial
Society for Science and Technology
Año de publicación
2021
ISSN
2186-4942
ISSN
2186-4942
Idioma
Inglés
Copiado