Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Adjusted calcium concentration as a predictor of ionized hypocalcemia in hypoalbuminemic dogs

Fiamma De Witte et al · Oxford University Press · 2021

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Abstract Background Ionized calcium (iCa) is the biologically active fraction of total calcium (tCa) with clinical relevance to evaluate calcium homeostasis, but not all primary veterinarians have access to serum iCa. Formulas that adjust tCa to correct for variability in serum protein concentrations were not designed to predict iCa and are considered unreliable surrogates for iCa. Objectives To determine whether adjusted calcium concentration (aCa) can predict ionized hypocalcemia in hypoalbuminemic dogs without hyperphosphatemia. Animals A total of 262 hypoalbuminemic dogs without hyperphosphatemia. Methods Retrospective review of paired tCa and iCa. Patients were included if serum albumin concentration was ≤2.5 g/L and serum phosphorus concentration was ≤5 mg/dL. The aCa was calculated using tCa (mg/dL) − serum albumin concentration (g/dL) + 3.5 (g/dL). Sensitivity, specificity, positive (PPVs) and negative (NPVs) predictive values, and accuracy were determined for tCa and aCa at predicting any (<1.13 mmol/L) and moderate (<1.02 mmol/L) ionized hypocalcemia. Patients also were stratified into mild‐to‐moderate (2.0‐2.5 g/dL) and severe hypoalbuminemia (<2.0 g/dL). Results A total of 4296 dogs had paired results of which 262 met the inclusion criteria. Of these, 35 (13.4%) dogs had iCa < 1.13 mmol/L and 13 dogs (5.0%) had concentrations <1.02 mmol/L. The sensitivity, specificity, NPVs and PPVs of a decreased tCa and aCa for detecting moderate ionized hypocalcemia were 100% and 92.3%, 57.8% and 94.8%, 100% and 99.6%, and 11.0% and 48.2%, respectively, and accuracy was 60.0% and 94.7%, respectively. Conclusions A low aCa was useful to detect ionized hypocalcemia in hypoalbuminemic nonhyperphosphatemic dogs. A normal aCa indicated that moderate ionized hypocalcemia was unlikely.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, F. D. W. E. (2021). Adjusted calcium concentration as a predictor of ionized hypocalcemia in hypoalbuminemic dogs. https://doi.org/10.1111/jvim.16247

MLA

al, Fiamma De Witte et. "Adjusted calcium concentration as a predictor of ionized hypocalcemia in hypoalbuminemic dogs." 2021. https://doi.org/10.1111/jvim.16247.

Chicago

al, Fiamma De Witte et. 2021. "Adjusted calcium concentration as a predictor of ionized hypocalcemia in hypoalbuminemic dogs.". https://doi.org/10.1111/jvim.16247.

Harvard

al, F. D. W. E. 2021, Adjusted calcium concentration as a predictor of ionized hypocalcemia in hypoalbuminemic dogs, Oxford University Press, available at: https://doi.org/10.1111/jvim.16247 [Accessed 5 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Adjusted calcium concentration as a predictor of ionized hypocalcemia in hypoalbuminemic dogs
Autore / collaboratori
Fiamma De Witte et al
Editore
Oxford University Press
Anno di pubblicazione
2021
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato