Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter

Martens Daan et al · Wiley · 2017

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

The Mach-Zehnder interferometer (MZI) and the Vernier-cascade are highly responsive photonic sensors with large design freedom. They are therefore very suitable for interrogation through a broadband source and an on-chip spectral filter, a sensing scheme that is well equipped for point-of-care applications. In this work, the MZI is shown to outperform the Vernier-cascade through a better minimum detectable wavelength shift as well as a higher power efficiency, indicating its superiority in this sensing scheme. Fabricated MZIs yield bulk detection limits down to 8.8×10−7 refractive index units (RIU) in a point-of-care compatible measuring setup, indicating the potential of the proposed sensing scheme.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. D. E. (2017). Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter. https://doi.org/10.1515/nanoph-2016-0181

MLA

al, Martens Daan et. "Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter." 2017. https://doi.org/10.1515/nanoph-2016-0181.

Chicago

al, Martens Daan et. 2017. "Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter.". https://doi.org/10.1515/nanoph-2016-0181.

Harvard

al, M. D. E. 2017, Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter, Wiley, available at: https://doi.org/10.1515/nanoph-2016-0181 [Accessed 6 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Comparison between Vernier-cascade and MZI as transducer for biosensing with on-chip spectral filter
Autore / collaboratori
Martens Daan et al
Editore
Wiley
Anno di pubblicazione
2017
ISSN
2192-8606
ISSN
2192-8606
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato