Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope

Lisa De Lange et al · Oxford University Press · 2021

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

Questa pubblicazione seriale contiene 149 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

Abstract Rate‐adaptive single chamber pacemakers with accelerometer, closed loop stimulation (CLS), and remote monitoring functionality (Eluna 8 SR‐T, Biotronik, SE & Co, Germany) were implanted in 3 miniature donkeys with third‐degree atrioventricular block and syncope. After recovery, different pacemaker programming modes were tested at rest, during stress without physical exercise and during physical exercise. Pacing rates were compared to actual atrial rates and showed that CLS functionality allowed physiological heart rate adaptation. A transmitter installed in the stable provided wireless connection of the pacemaker to the internet. Home monitoring was activated which performed daily wireless transmission of pacemaker functional measurements to an online server allowing diagnosis of pathological arrhythmias and pacemaker malfunction from a distance. Closed loop stimulation and remote monitoring functionality resulted in nearly physiological rate adaptation and allowed remote “from‐the‐stable” patient follow‐up.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, L. D. L. E. (2021). Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope. https://doi.org/10.1111/jvim.16305

MLA

al, Lisa De Lange et. "Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope." 2021. https://doi.org/10.1111/jvim.16305.

Chicago

al, Lisa De Lange et. 2021. "Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope.". https://doi.org/10.1111/jvim.16305.

Harvard

al, L. D. L. E. 2021, Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope, Oxford University Press, available at: https://doi.org/10.1111/jvim.16305 [Accessed 6 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Successful application of closed loop stimulation pacemakers with remote monitoring in 3 miniature donkeys with syncope
Autore / collaboratori
Lisa De Lange et al
Editore
Oxford University Press
Anno di pubblicazione
2021
ISSN
0891-6640
ISSN
0891-6640
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato