Voltar aos resultados
Registro bibliográfico · Consulta e acesso
Artículo

Gold-nanourchin complexed silicon dioxide-probe on gap-fingered interdigitated electrode surface for Parkinson’s Disease determination by current–volt measurement

Xiaohong Li et al · SAGE Publishing · 2021

Acesso aberto disponível
Leitura rápida. Confira os dados básicos do recurso e acesse o conteúdo pelo botão principal. Esta ficha mostra apenas as informações necessárias para identificar, citar e abrir a obra.

Acesso ao recurso

Acesse o conteúdo pela opção principal ou escolha outra fonte disponível.

DOAJ DOAJ Articles
Entrar por DOAJ
Acesso principal

Acesso aberto disponível

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Abrir recurso

Resumo

Descripción general del contenido del recurso.

Parkinson’s disease (PD) is a nervous disorder, affects physical movement, and leads to difficulty in balancing, walking, and coordination. A novel sensor is mandatory to determine PD and monitor the progress of the treatment. Neurofilament light chain (NfL) has been recognized as a good biomarker for PD and also helps to distinguish between PD and atypical PD syndromes. Immunosensor was generated by current–volt measurement on gap-fingered interdigitated electrode with silicon dioxide surface to determine NfL level. To enhance the detection, anti-NfL antibody was complexed with gold-nanourchin and immobilized on the sensing electrode. The current–volt response was gradually increased at the linear detection range from 100 fM to 1 nM. Limit of detection and sensitivity were 100 fM with the signal-to-noise ratio at n = 3 on a linear curve ( y = 0.081 x + 1.593; R 2 = 0.9983). Limit of quantification falls at 1 pM and high performance of the sensor was demonstrated by discriminating against other neurogenerative disease markers, in addition, it was reproducible even in serum-spiked samples. This method of detection system aids to measure the level of NfL and leads to determine the condition with PD.

Como citar

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, X. L. E. (2021). Gold-nanourchin complexed silicon dioxide-probe on gap-fingered interdigitated electrode surface for Parkinson’s Disease determination by current–volt measurement. https://doi.org/10.1177/1847980420987352

MLA

al, Xiaohong Li et. "Gold-nanourchin complexed silicon dioxide-probe on gap-fingered interdigitated electrode surface for Parkinson’s Disease determination by current–volt measurement." 2021. https://doi.org/10.1177/1847980420987352.

Chicago

al, Xiaohong Li et. 2021. "Gold-nanourchin complexed silicon dioxide-probe on gap-fingered interdigitated electrode surface for Parkinson’s Disease determination by current–volt measurement.". https://doi.org/10.1177/1847980420987352.

Harvard

al, X. L. E. 2021, Gold-nanourchin complexed silicon dioxide-probe on gap-fingered interdigitated electrode surface for Parkinson’s Disease determination by current–volt measurement, SAGE Publishing, available at: https://doi.org/10.1177/1847980420987352 [Accessed 6 Aug. 2026].

Compartilhar e imprimir

Salve a ficha, copie o link permanente ou imprima em PDF.

Exportar referência

Exporte o registro nos formatos mais comuns para usar em um gerenciador bibliográfico.

Detalhes do recurso

Informações bibliográficas para confirmar que este é o material correto.

Título
Gold-nanourchin complexed silicon dioxide-probe on gap-fingered interdigitated electrode surface for Parkinson’s Disease determination by current–volt measurement
Autor / colaboradores
Xiaohong Li et al
Editora
SAGE Publishing
Ano de publicação
2021
ISSN
1847-9804
ISSN
1847-9804
Idioma
Inglés
Copiado