Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device

Cao, Dingcai et al · Taylor & Francis · 2014

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

CONICET Digital CONICET Digital OAI-PMH
Entrar por CONICET Digital
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

The intrinsic circadian clock requires photoentrainment to synchronize the 24-hour solar day. Therefore, light stimulation is an important component of chronobiological research. Currently, the chronobiological research field overwhelmingly uses photopic illuminance that is based on the luminous efficiency function, V(λ), to quantify light levels. However, recent discovery of intrinsically photosensitive retinal ganglion cells (ipRGCs), which are activated by self-containing melanopsin photopigment and also by inputs from rods and cones, makes light specification using a one-dimensional unit inadequate. Since the current understanding of how different photoreceptor inputs contribute to the circadian system through ipRGCs is limited, it is recommended to specify light in terms of the excitations of five photoreceptors (S-, M-, L-cones, rods and ipRGCs). In the current study, we assessed whether the spectral outputs from a commercially available spectral watch (i.e., Actiwatch Spectrum) could be used to estimate photoreceptor excitations. Based on the color sensor spectral sensitivity functions from a previously published work, as well as from our measurements, we computed spectral outputs in the long-wavelength range (R), middle-wavelength range (G), short-wavelength range (B) and broadband range (W) under 52 CIE illuminants (25 daylight illuminants, 27 fluorescent lights). We also computed the photoreceptor excitations for each illuminant using human spectral sensitivity functions. Linear regression analyses indicated that the Actiwatch spectral outputs could predict photoreceptor excitations reliably, under the assumption of linear responses of the Actiwatch color sensors. In addition, R, G, B outputs could classify illuminant types (fluorescent vs. daylight illuminants) satisfactorily. However, the assessment of actual Actiwatch recording under several testing light sources showed that the spectral outputs were subject to great nonlinearity, leading to less accurate estimation of photoreceptor excitations. Based on our analyses, we recommend that each spectral watch should be calibrated to measure spectral sensitivity functions and linearization characteristics for each sensor to have an accurate estimation of photoreceptor excitations. The method we provided to estimate photoreceptor excitations from the outputs of spectral watches could be used for chronobiological studies that can tolerate an error in the range of 0.2-0.5 log units. Our method can be easily expanded to incorporate linearization functions to have more accurate estimations. Fil: Cao, Dingcai. University Of Illinois; Estados Unidos Fil: Barrionuevo, Pablo Alejandro. University Of Illinois; Estados Unidos. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Cao, D. E. A. (2014). Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device. http://hdl.handle.net/11336/10613

MLA

Cao, Dingcai et al. "Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device." 2014. http://hdl.handle.net/11336/10613.

Chicago

Cao, Dingcai et al. 2014. "Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device.". http://hdl.handle.net/11336/10613.

Harvard

Cao, D. E. A. 2014, Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device, Taylor & Francis, available at: http://hdl.handle.net/11336/10613 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Estimating photoreceptor excitations from spectral outputs of a personal light exposure measurement device
Autore / collaboratori
Cao, Dingcai et al
Editore
Taylor & Francis
Anno di pubblicazione
2014
ISSN
0742-0528
ISSN
0742-0528
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato