Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions

López, Damián Alejandro et al · Springer · 2008

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

CONICET Digital CONICET Digital OAI-PMH
Entrar por CONICET Digital
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

Titanium and cobalt alloys, as well as some stainless steels, are among the most frequently used materials in orthopaedic surgery. In industrialized countries, stainless steel devices are used only for temporary implants due to their lower corrosion resistance in physiologic media when compared to other alloys. However, due to economical reasons, the use of stainless steel alloys for permanent implants is very common in developing countries. The implantation of foreign bodies is sometimes necessary in the modern medical practice. However, the complex interactions between the host and the can implant weaken the local immune system, increasing the risk of infections. Therefore, it is necessary to further study these materials as well as the characteristics of the superficial film formed in physiologic media in infection conditions in order to control their potential toxicity due to the release of metallic ions in the human body. This work presents a study of the superficial composition and the corrosion resistance of AISI 316L stainless steel and the influence of its main alloying elements when they are exposed to an acidic solution that simulates the change of pH that occurs when an infection develops. Aerated simulated body fluid (SBF) was employed as working solution at 37°C. The pH was adjusted to 7.25 and 4 in order to reproduce normal body and disease state respectively. Corrosion resistance was measured by means of electrochemical impedance spectroscopy (EIS) and anodic polarization curves. Fil: López, Damián Alejandro. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mar del Plata. Instituto de Investigaciones en Ciencia y Tecnología de Materiales. Universidad Nacional de Mar del Plata. Facultad de Ingeniería. Instituto de Investigaciones en Ciencia y Tecnología de Materiales; Argentina Fil: Durán, Alicia. Instituto de Ceramica y Vidrio de Madrid; España

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

López, D. A. E. A. (2008). Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions. http://hdl.handle.net/11336/67973

MLA

López, Damián Alejandro et al. "Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions." 2008. http://hdl.handle.net/11336/67973.

Chicago

López, Damián Alejandro et al. 2008. "Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions.". http://hdl.handle.net/11336/67973.

Harvard

López, D. A. E. A. 2008, Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions, Springer, available at: http://hdl.handle.net/11336/67973 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Electrochemical characterization of AISI 316L stainless steel in contact with simulated body fluid under infection conditions
Autore / collaboratori
López, Damián Alejandro et al
Editore
Springer
Anno di pubblicazione
2008
ISSN
2137-2144
ISSN
2137-2144
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato