Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Libro

Intraocular light scatter in eyes with Boston type 1 Keratoprosthesis

Shorter, Ellen et al · American Academy of Optometry · 2018

Testo completo ad accesso aperto
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

CONICET Digital CONICET Digital OAI-PMH
Entrar por CONICET Digital
Accesso principale

Testo completo ad accesso aperto

Texto completo identificado como acceso abierto.
Apri testo

Riepilogo

Descripción general del contenido del recurso.

Purpose Boston Keratoprosthesis (KPro) has been proven to be a viable option for visual rehabilitation in patients with poor prognosis for penetrating keratoplasty, and its use has steadily increased during the past decade. An improved design and postoperative management have led to longer retention rates, fewer complications and overall better outcomes. Many patients complain of significant glare and visual dysfunction despite improved visual acuity. This issue motivated us to objectively measure light scatter in eyes with KPro devices.Methods Light scatter was measured using OCULUS C-Quant device (Arlington, WA). The amount of scatter was compared between 21 eyes with Boston KPro Type 1 and VA of 20/150 or better to 13 healthy control eyes. The measurements were repeated at more than one visit. Scatter measurements were also repeated on 11 eyes with Boston KPro Type 1 using a black iris occluder Orion Prosthetic contact lens(Orion Vision Group, Marietta, GA). The contact lens was polymacon 38% material, plano power, base curve 8.6, diameter 14.3, 12.25 black occluder iris with a 5.0mm clear pupil.Results The mean age of the KPro group was 55.5 years and 53.6 years for the control group. Mean VA was 0.47 logMAR and 0.00 logMAR for the KPro and control group respectively. Intraocular light scatter was found to be significantly higher in patients with KPro compared to healthy control subjects (logS values of 2.34 ± 0.15 and 1.29 ± 0.17 respectively, p<0.01). Light scatter in eyes with PMMA KPro devices (logS 2.49 ± 0.19; n=16) was higher than in eyes with titanium KPro devices (logS 1.87 ± 0.15; n=5). The LogS value was significantly lower for eyes with PMMA backplate KPro devices fit with iris occluder prosthetic lens (1.71 vs 2.42, P = < 0.05; n=11).Conclusion Glare is a common complaint by many patients with KPro devices. Light scatter measured in this study showed significantly higher values in eyes with KPro devices compared to healthy eyes. Possibly due to its opaque nature, the titanium backplate model appears to produce less light scatter than PMMA backplate model. Prosthetic contact lenses may serve a role to reduce light scatter in individuals with KPro devices and should be considered as an option for symptomatic patients. Fil: Shorter, Ellen. University of Illinois; Estados Unidos Fil: Karas, Faras. University of Illinois; Estados Unidos

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Shorter, E. E. A. (2018). Intraocular light scatter in eyes with Boston type 1 Keratoprosthesis. American Academy of Optometry. http://hdl.handle.net/11336/276987

MLA

Shorter, Ellen et al. Intraocular light scatter in eyes with Boston type 1 Keratoprosthesis. American Academy of Optometry, 2018. http://hdl.handle.net/11336/276987.

Chicago

Shorter, Ellen et al. 2018. Intraocular light scatter in eyes with Boston type 1 Keratoprosthesis. American Academy of Optometry. http://hdl.handle.net/11336/276987.

Harvard

Shorter, E. E. A. 2018, Intraocular light scatter in eyes with Boston type 1 Keratoprosthesis, American Academy of Optometry, available at: http://hdl.handle.net/11336/276987 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Intraocular light scatter in eyes with Boston type 1 Keratoprosthesis
Autore / collaboratori
Shorter, Ellen et al
Editore
American Academy of Optometry
Anno di pubblicazione
2018
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato