Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Fabrication of a novel naltrexone biosensor based on a computationally engineered nanobiocomposite

Gholivand, Mohammad Bagher et al · Elsevier Science · 2014

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

CONICET Digital CONICET Digital OAI-PMH
Entrar por CONICET Digital
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

A computationally engineered impedimetric naltrexone (NLT) biosensor based on immobilization of bovine serum albumin (BSA) onto fullerene-C60/glassy carbon electrode (FLR/GCE) has been developed using initial characterization by computational methods and complementing them by experimental ones. Computational results showed that BSA hydrophobically binds to FLR which is energetically favorable and leads to the spontaneous formation of the stable nanobiocomposite and also showed that interaction of NLT with BSA is mainly driven by hydrogen bonding and hydrophobic interactions. Besides complementing the computational studies, experimental results showed that addition of FLR to the surface of the electrode facilitated electron transfer reactions, and also showed that the presence of BSA inhibits the interfacial electron transfer in some extent due to the nonconductive properties of BSA. The presence of NLT may form a negatively charged electroactive complex with BSA which repels the negatively charged redox probe and decelerates interfacial electron transfer leading to obvious faradaic impedance change. The faradaic impedance responses were linearly related to naltrexone concentration between 0.1 nM and 80 nM and limit of detection (LOD) was calculated to be 0.01 nM (3Sb/b). Finally, the proposed biosensor was successfully applied to determination of NLT in urine samples of both healthy and addict volunteers. Fil: Gholivand, Mohammad Bagher. Razi University. Faculty of Chemistry; Irán Fil: Jalalvand, Ali R.. Razi University. Faculty of Chemistry; Irán. Universidad Nacional del Litoral; Argentina

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Gholivand, M. B. E. A. (2014). Fabrication of a novel naltrexone biosensor based on a computationally engineered nanobiocomposite. http://hdl.handle.net/11336/16035

MLA

Gholivand, Mohammad Bagher et al. "Fabrication of a novel naltrexone biosensor based on a computationally engineered nanobiocomposite." 2014. http://hdl.handle.net/11336/16035.

Chicago

Gholivand, Mohammad Bagher et al. 2014. "Fabrication of a novel naltrexone biosensor based on a computationally engineered nanobiocomposite.". http://hdl.handle.net/11336/16035.

Harvard

Gholivand, M. B. E. A. 2014, Fabrication of a novel naltrexone biosensor based on a computationally engineered nanobiocomposite, Elsevier Science, available at: http://hdl.handle.net/11336/16035 [Accessed 9 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Fabrication of a novel naltrexone biosensor based on a computationally engineered nanobiocomposite
Autore / collaboratori
Gholivand, Mohammad Bagher et al
Editore
Elsevier Science
Anno di pubblicazione
2014
ISSN
0141-8130
ISSN
0141-8130
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato