Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Ultra-sonografia transvaginal do colo para a predição do parto pré-termo em pacientes sintomáticas com bolsa íntegra Transvaginal ultrasound of the cervix for predicting premature delivery in symptomatic patients with intact membranes

Lívia Teresa Moreira Rios et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2006

Materiale supplementare disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.
Pubblicazione seriale

A FEBRASGO e o Novo Ano

Questa pubblicazione seriale contiene 195 contenuti correlati.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Materiale supplementare disponibile

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Apri materiale

Riepilogo

Descripción general del contenido del recurso.

OBJETIVOS: avaliar a utilidade do comprimento cervical ultra-sonográfico para a predição do parto em gestantes com contrações uterinas persistentes e bolsa íntegra. MÉTODOS: realizou-se estudo observacional, prospectivo, do tipo coorte no qual foram incluídas 45 gestantes internadas em nossa instituição entre a 22ª e a 34ª semana. Ultra-sonografia transvaginal do colo foi realizada uma única vez, após completado um ciclo de tocólise endovenosa, com aferição do comprimento, conforme critérios descritos previamente. Os achados ultra-sonográficos não foram utilizados para o diagnóstico ou conduta obstétrica. O desfecho estudado foi a ocorrência de parto pré-termo (<37 semanas). A análise estatística fundamentou-se em método de regressão logística univariada para determinar a significância do comprimento cervical para a predição do parto pré-termo. O nível de significância adotado foi de 5% (p<0,05) e o intervalo de confiança foi de 95% (IC 95%). RESULTADOS: a incidência de parto pré-termo foi de 51,1% (23/45). O comprimento cervical associou-se de forma significativa ao desfecho da gestação (p<0,0001). Após construção de curva característica operatória do receptor, um comprimento cervical de 20 mm revelou-se como melhor ponto de corte para a predição do parto pré-termo (sensibilidade: 86,9%; especificidade: 81,8%; valor preditivo positivo: 83,3% e valor preditivo negativo: 85,7%). A área calculada abaixo da curva característica operatória do receptor foi de 0,91 (IC 95%: 0.79-0.97; p<0,0001). CONCLUSÕES: nas mulheres com contrações uterinas persistentes e bolsa íntegra, em tratamento para trabalho de parto pré-termo, um comprimento cervical inferior a 20 mm demonstrou maior probabilidade de parto pré-termo. A ultra-sonografia transvaginal pode melhorar a acurácia diagnóstica em gestantes sintomáticas.<br>PURPOSE: to assess the role of ultrasonographic cervical length in predicting premature labor in patients presenting persistent uterine contractions and intact membranes. METHODS: a prospective observational cohort study was performed in 45 women admitted to our hospital between 22 and 34 weeks of gestation. Transvaginal sonographic evaluation of the cervix was performed once in the women who had completed a course of parenteral tocolysis. The cervical length was obtained according to criteria reported previously. Cervical sonographic findings were not used in diagnosis and management. Outcome variable was the occurrence of preterm delivery (<37 weeks). Statistical analysis consisted of univariate method with the purpose of determining the significant contribution of cervical length to the prediction of preterm delivery. The adopted significance level was 5% (p<0,05) and the confidence interval was 95% (95% CI). RESULTS: the incidence of preterm delivery was 51.11% (23/45). Cervical length was significantly associated with the outcome (p<0.0001). Receiver operating characteristic curve analysis showed that a cervical length of 20 mm was the best cutoff in predicting preterm delivery (sensitivity 86.9%; specificity 81.8%; positive predictive value 83.3%; negative predictive value 85.7%). The calculated area under the curve was 0.91 (95% CI: 0.79-0.97; p<0.0001). CONCLUSIONS: among women with persistent uterine contractions and intact membranes treated for preterm labor, a cervical length of less than 20 mm demonstrated a high likelihood of preterm birth. Transvaginal ultrasound may improve the accuracy of diagnosis in symptomatic women.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, L. T. M. R. E. (2006). Ultra-sonografia transvaginal do colo para a predição do parto pré-termo em pacientes sintomáticas com bolsa íntegra Transvaginal ultrasound of the cervix for predicting premature delivery in symptomatic patients with intact membranes. https://doi.org/10.1590/S0100-72032006001100006

MLA

al, Lívia Teresa Moreira Rios et. "Ultra-sonografia transvaginal do colo para a predição do parto pré-termo em pacientes sintomáticas com bolsa íntegra Transvaginal ultrasound of the cervix for predicting premature delivery in symptomatic patients with intact membranes." 2006. https://doi.org/10.1590/S0100-72032006001100006.

Chicago

al, Lívia Teresa Moreira Rios et. 2006. "Ultra-sonografia transvaginal do colo para a predição do parto pré-termo em pacientes sintomáticas com bolsa íntegra Transvaginal ultrasound of the cervix for predicting premature delivery in symptomatic patients with intact membranes.". https://doi.org/10.1590/S0100-72032006001100006.

Harvard

al, L. T. M. R. E. 2006, Ultra-sonografia transvaginal do colo para a predição do parto pré-termo em pacientes sintomáticas com bolsa íntegra Transvaginal ultrasound of the cervix for predicting premature delivery in symptomatic patients with intact membranes, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032006001100006 [Accessed 7 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Ultra-sonografia transvaginal do colo para a predição do parto pré-termo em pacientes sintomáticas com bolsa íntegra Transvaginal ultrasound of the cervix for predicting premature delivery in symptomatic patients with intact membranes
Autore / collaboratori
Lívia Teresa Moreira Rios et al
Editore
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Anno di pubblicazione
2006
ISSN
0100-7203
ISSN
0100-7203
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato