Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

One-stop automated diagnostic system for active sacroiliitis in three-dimensional magnetic resonance images using artificial intelligent models: a retrospective study

Xiaojian Ji et al · Elsevier · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Background: Axial spondyloarthritis (axSpA) can potentially progress to ankylosing spondylitis, and diagnostic delay may lead to irreversible structural damage. Although sacroiliac joint magnetic resonance imaging (MRI) can detect bone marrow edema (BME) for early diagnosis, the complex etiologies and reliance on expert interpretation impede efficient identification in chronic low back pain populations. Therefore, we developed an artificial intelligence (AI) system that integrates MRI analysis and automates report generation to facilitate the detection of active sacroiliitis and BME quantification. Methods: This retrospective study analyzed 691 patients (540 with axSpA and 151 with non-spondyloarthritis) from the Chinese People’s Liberation Army General Hospital (2011–2023). Data were split into training and testing cohorts (4:1 ratio), with five-fold cross-validation applied to the training set. The system comprises four modules: (1) image preprocessing (intensity normalization), (2) coarse-to-fine 3D U-Net-based quadrant segmentation, (3) ResNet18-driven edema recognition (depth/intensity classification), and (4) diagnostic report generation using the QWEN large language model. Results: Among 691 patients (335 active sacroiliitis-positive and 356 negative), the AI system achieved Spondyloarthritis Research Consortium of Canada (SPARCC) scores of (15.12±10.73) vs. (0.88±1.13) in positive versus negative groups, respectively. The quadrant segmentation module achieved DICE similarity coefficients above 0.7 on the training, validation, and testing datasets. The edema inflammation, depth, and intensity classifiers exhibited good performance on the testing dataset, with balanced accuracies of 77.54%, 76.26%, and 80.91%, and area under the curve values of 0.85, 0.87, and 0.92, respectively. The intraclass correlation coefficient between SPARCC scores by our system and those by rheumatologists was 0.84 on the testing dataset. At the patient-level, our system achieved 90.81% sensitivity for diagnosis of active sacroiliitis on the testing dataset. Conclusion: The developed automated system enhances axSpA diagnostic efficiency by automating the identification of active sacroiliitis and enabling quantitative assessment of BME.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, X. J. E. (2026). One-stop automated diagnostic system for active sacroiliitis in three-dimensional magnetic resonance images using artificial intelligent models: a retrospective study. https://doi.org/10.1016/j.imed.2025.07.005

MLA

al, Xiaojian Ji et. "One-stop automated diagnostic system for active sacroiliitis in three-dimensional magnetic resonance images using artificial intelligent models: a retrospective study." 2026. https://doi.org/10.1016/j.imed.2025.07.005.

Chicago

al, Xiaojian Ji et. 2026. "One-stop automated diagnostic system for active sacroiliitis in three-dimensional magnetic resonance images using artificial intelligent models: a retrospective study.". https://doi.org/10.1016/j.imed.2025.07.005.

Harvard

al, X. J. E. 2026, One-stop automated diagnostic system for active sacroiliitis in three-dimensional magnetic resonance images using artificial intelligent models: a retrospective study, Elsevier, available at: https://doi.org/10.1016/j.imed.2025.07.005 [Accessed 8 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
One-stop automated diagnostic system for active sacroiliitis in three-dimensional magnetic resonance images using artificial intelligent models: a retrospective study
Autore / collaboratori
Xiaojian Ji et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
2667-1026
ISSN
2667-1026
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato