Torna ai risultati
Scheda bibliografica · Consultazione e accesso
Artículo

Comparison of pre-analytical properties of blood collection systems for the diagnosis of diabetes mellitus

Juliane Flindt et al · Elsevier · 2026

Accesso aperto disponibile
Lettura rapida. Controlla i dati essenziali della risorsa e accedi al contenuto con il pulsante principale. La scheda mostra solo le informazioni necessarie per identificare, citare e aprire l’opera.

Accesso alla risorsa

Apri il contenuto dall’opzione principale o scegli un’altra fonte disponibile.

DOAJ DOAJ Articles
Entrar por DOAJ
Accesso principale

Accesso aperto disponibile

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Apri risorsa

Riepilogo

Descripción general del contenido del recurso.

Background: Proper pre-analytical handling of blood samples is essential for reliable glucose measurement and for the accurate diagnosis and monitoring of diabetes mellitus. This study aimed to compare glucose concentrations in serum, lithium heparin (Li-Heparin), sodium fluoride citrate (NaF-Citrate), and sodium fluoride (NaF) plasma. Methods: Blood samples from 45 healthy volunteers were collected in Li-Heparin, NaF-Citrate, and serum tubes. Serum was stored at room temperature (RT) for up to 30 min, Li-Heparin whole blood in an ice-water slurry, and NaF-Citrate and Li-Heparin whole blood at RT for up to 10 min. Glucose was measured using the Cobas 8000 c701 analyzer. Additionally, internal routine laboratory data (n > 85,000) were analysed following the switch from NaF to NaF-Citrate tubes in 2015. Results: NaF-Citrate plasma showed the highest positive deviations, up to 3.11% compared with both reference conditions. Li-Heparin plasma at RT was 1.17 % higher than Li-Heparin plasma on ice. Serum glucose did not differ significantly from Li-Heparin plasma on ice. In routine data, the introduction of NaF-Citrate tubes resulted in an average increase of 10.5% in measured glucose concentrations in 2016. Conclusion: Glucose concentrations measured in NaF-Citrate plasma and Li-Heparin plasma (ice or RT) within 30 min after blood collection are not comparable. According to ADA and WHO diagnostic criteria, switching to NaF-Citrate tubes increased the proportion of patients with impaired fasting glucose by 16.9% and impaired glucose tolerance by 8.8%. NaF-Citrate tubes are recommended when immediate centrifugation and plasma separation cannot be ensured.

Come citare

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, J. F. E. (2026). Comparison of pre-analytical properties of blood collection systems for the diagnosis of diabetes mellitus. https://doi.org/10.1016/j.plabm.2026.e00534

MLA

al, Juliane Flindt et. "Comparison of pre-analytical properties of blood collection systems for the diagnosis of diabetes mellitus." 2026. https://doi.org/10.1016/j.plabm.2026.e00534.

Chicago

al, Juliane Flindt et. 2026. "Comparison of pre-analytical properties of blood collection systems for the diagnosis of diabetes mellitus.". https://doi.org/10.1016/j.plabm.2026.e00534.

Harvard

al, J. F. E. 2026, Comparison of pre-analytical properties of blood collection systems for the diagnosis of diabetes mellitus, Elsevier, available at: https://doi.org/10.1016/j.plabm.2026.e00534 [Accessed 10 Aug. 2026].

Condividi e stampa

Salva la scheda, copia il link permanente o stampala in PDF.

Esporta riferimento

Esporta il record nei formati più comuni per usarlo con un gestore bibliografico.

Dettagli della risorsa

Informazioni bibliografiche utili per verificare che sia il materiale corretto.

Titolo
Comparison of pre-analytical properties of blood collection systems for the diagnosis of diabetes mellitus
Autore / collaboratori
Juliane Flindt et al
Editore
Elsevier
Anno di pubblicazione
2026
ISSN
2352-5517
ISSN
2352-5517
Lingua
Inglés

Soggetti

Esplora risorse correlate a partire da questi soggetti.

Copiato