Back to results
Bibliographic record · Consultation and access
Artículo

Doppler signal analysis of the tricuspid valve in healthy fetuses during the first trimester: a cohort study

Gustavo Fonseca de Albuquerque Souza et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2026

Open-access full text
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A FEBRASGO e o Novo Ano

This serial publication contains 195 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open-access full text

Texto completo identificado como acceso abierto.
Open text

Summary

Descripción general del contenido del recurso.

Abstract Objective: This study aimed to characterize tricuspid valve sound signals in healthy fetuses during the first trimester of pregnancy using Doppler ultrasound and computational analysis. Methods: A cohort of pregnant women at 11–14 weeks of normal-risk gestation was assessed at the Instituto de Medicina Integral Prof. Fernando Figueira (IMIP) between December 2019 and May 2020. Eligible participants were over 18 years old with no pregnancy complications. Doppler recordings of the fetal tricuspid valve were obtained, and linear (wave duration) and non-linear analyses were performed, including approximate entropy (ApEn), Lempel-Ziv complexity (LZC), and detrended fluctuation analysis (DFA). Follow-up in the second trimester with a fetal medicine team and postnatal follow-up with physical examination by an experienced neonatology team confirmed normal cardiac results. Results: Early diastolic (E) wave presented a mean duration of 70.89±9.26 ms, with ApEn 0.25±0.15, LZC 0.77±0.15, and DFA 0.73. Atrial contraction (A) wave had 79.77±7.56 ms, ApEn 0.25±0.15, LZC 0.77±0.19, and DFA 0.52. Systole showed 225.95±15.88 ms, ApEn 0.15±0.17, LZC 0.78±0.15, and DFA 0.75. Diastole had 150.66±13.99 ms, ApEn 0.18±0.11, LZC 0.83±0.22, and DFA 0.66. The full cardiac cycle lasted 376.61±16.40 ms, with ApEn 0.18±0.11, LZC 0.83±0.22, and DFA 0.81. The diastole/cardiac cycle ratio was 0.4±0.3, with ApEn 0.22±0.12, LZC 0.72±0.15, and DFA 0.62. Conclusion: This study offers a detailed characterization of tricuspid valve wave segments in healthy fetuses during early gestation. The integration of linear and non-linear analyses may enhance our understanding of fetal cardiac physiology. Further research is needed to evaluate whether these parameters can assist in the early detection of congenital heart diseases. We highlight the potential of these parameters for early screening of congenital heart disease and chromosomal abnormalities, while emphasizing the need for further studies to confirm their diagnostic value.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, G. F. D. A. S. E. (2026). Doppler signal analysis of the tricuspid valve in healthy fetuses during the first trimester: a cohort study. https://doi.org/10.61622/rbgo/2026rbgo101

MLA

al, Gustavo Fonseca de Albuquerque Souza et. "Doppler signal analysis of the tricuspid valve in healthy fetuses during the first trimester: a cohort study." 2026. https://doi.org/10.61622/rbgo/2026rbgo101.

Chicago

al, Gustavo Fonseca de Albuquerque Souza et. 2026. "Doppler signal analysis of the tricuspid valve in healthy fetuses during the first trimester: a cohort study.". https://doi.org/10.61622/rbgo/2026rbgo101.

Harvard

al, G. F. D. A. S. E. 2026, Doppler signal analysis of the tricuspid valve in healthy fetuses during the first trimester: a cohort study, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.61622/rbgo/2026rbgo101 [Accessed 5 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Doppler signal analysis of the tricuspid valve in healthy fetuses during the first trimester: a cohort study
Author / contributors
Gustavo Fonseca de Albuquerque Souza et al
Publisher
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Publication year
2026
ISSN
0100-7203
ISSN
0100-7203
Language
English

Subjects

Explore related resources through these subjects.

Copied