Back to results
Bibliographic record · Consultation and access
Artículo

Transparent glass slab thickness measurement by binary-spot focus signal

Aguilar, Andrés Daniel et al · Sociedad Española de Óptica · 2019

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

CONICET Digital CONICET Digital OAI-PMH
Entrar por CONICET Digital
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Los sistemas de error de foco basados en el principio astigmático que utilizan detectores de cuatro cuadrantes como elemento generador de señal han sido usados ampliamente en una gran variedad de aplicaciones. Sin embargo, su principio de funcionamiento no es particularmente adecuado para medidas que involucran más de un spot. En este trabajo proponemos un nuevo método que usa un CCD como dispositivo de detección y un método de procesar los datos adquiridos. Un efecto secundario de este cambio es la pérdida del parámetro , clave en estas técnicas. Para superar este problema se propone un nuevo parámetro que llamamos señal de foco. El proceso de medición de espesor de una muestra transparente con dos caras reflectoras usando esta técnica también es presentado. Focus error systems based on the astigmatic principle relying on four quadrant photo detectors as the signal generation element have widely been used in many different applications. Nevertheless, its working principle is not particularly suitable for measurements involving more than one spot. In this work we propose a new method that uses a CCD as the detection device as well as a method of processing acquired data. A side effect of this change is the loss of the parameter key to these techniques. To overcome this issue a new parameter named focus signal is proposed. The thickness measuring process of a transparent sample with two reflective layers using this technique is also presented. Fil: Aguilar, Andrés Daniel. Universidad Tecnológica Nacional. Facultad Regional Delta; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

Aguilar, A. D. E. A. (2019). Transparent glass slab thickness measurement by binary-spot focus signal. http://hdl.handle.net/11336/175185

MLA

Aguilar, Andrés Daniel et al. "Transparent glass slab thickness measurement by binary-spot focus signal." 2019. http://hdl.handle.net/11336/175185.

Chicago

Aguilar, Andrés Daniel et al. 2019. "Transparent glass slab thickness measurement by binary-spot focus signal.". http://hdl.handle.net/11336/175185.

Harvard

Aguilar, A. D. E. A. 2019, Transparent glass slab thickness measurement by binary-spot focus signal, Sociedad Española de Óptica, available at: http://hdl.handle.net/11336/175185 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Transparent glass slab thickness measurement by binary-spot focus signal
Author / contributors
Aguilar, Andrés Daniel et al
Publisher
Sociedad Española de Óptica
Publication year
2019
ISSN
2171-8814
ISSN
2171-8814
Language
English

Subjects

Explore related resources through these subjects.

Copied