Back to results
Bibliographic record · Consultation and access
Artículo

Pseudo flow-injection ESR technique combining spin-trapping and application to the evaluation of superoxide scavenging capacity of phenolic compound

Yu Saito et al · Society for Science and Technology · 2014

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Evaluation methods of superoxide scavenging capacity have been studied by many researchers. One of the methods is a spin- trapping electron spin resonance (ESR) technique, in which 5,5-diemthyl-1-pyrroline 1-oxide (DMPO) was usually used as a spin-trapping reagent. In previous reports, the evaluation method based on a competition reaction and spin-trapping ESR technique were proposed. However, a big key issue and unavoidable problem remained in this evaluation. This is the rapid decrease of DMPO-O2- adduct by the following chemical reactions. Therefore, the initial signal intensity of DMPO-O2- has to be estimated with an approximation from a decreasing curve. This approximation, however, includes at least a thirty-second time lag before starting an ESR measurement. So, the measurement of a shorter time lag is required to obtain a more accurate initial intensity of DMPO-O2- adduct. In this study, the pseudo flow-injection ESR method using a peristaltic pump was adopted to inject the test solution directly into a quartz cell in ESR cavity. This method achieved a 10 times shorter time lag (ca. 3 seconds) compared with the previous method (ca. 30 seconds) using a hematocrit capillary. As a consequence, the initial signal intensity within 10 % error was obtained without any estimation. The second-order rate constants of the reaction between various phenolic compounds and superoxide were obtained as one of the applications of this method.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Y. S. E. (2014). Pseudo flow-injection ESR technique combining spin-trapping and application to the evaluation of superoxide scavenging capacity of phenolic compound. https://doi.org/10.11425/sst.3.151

MLA

al, Yu Saito et. "Pseudo flow-injection ESR technique combining spin-trapping and application to the evaluation of superoxide scavenging capacity of phenolic compound." 2014. https://doi.org/10.11425/sst.3.151.

Chicago

al, Yu Saito et. 2014. "Pseudo flow-injection ESR technique combining spin-trapping and application to the evaluation of superoxide scavenging capacity of phenolic compound.". https://doi.org/10.11425/sst.3.151.

Harvard

al, Y. S. E. 2014, Pseudo flow-injection ESR technique combining spin-trapping and application to the evaluation of superoxide scavenging capacity of phenolic compound, Society for Science and Technology, available at: https://doi.org/10.11425/sst.3.151 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Pseudo flow-injection ESR technique combining spin-trapping and application to the evaluation of superoxide scavenging capacity of phenolic compound
Author / contributors
Yu Saito et al
Publisher
Society for Science and Technology
Publication year
2014
ISSN
2186-4942
ISSN
2186-4942
Language
English

Subjects

Explore related resources through these subjects.

Copied