Back to results
Bibliographic record · Consultation and access
Artículo

Eficiência dos testes COPAN (Microplate e Single) na detecção de resíduos de antimicrobianos no leite Efficacy of COPAN (Microplate and Single kits) in detection of antimicrobials residues in milk

C.G.M.S.C. Tenório et al · Universidade Federal de Minas Gerais, Escola de Veterinária · 2009

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

Arquivo Brasileiro de Medicina Veterinária e Zootecnia

This serial publication contains 109 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Avaliou-se a eficiência dos testes microbiológicos COPAN (Microplate e Single) para detecção de resíduos de 13 antimicrobianos inoculados em leite isento de resíduos. Foram utilizadas quatro concentrações, sendo a primeira equivalente à metade do limite de detecção declarado pelo fabricante (C1); a segunda equivalente ao limite máximo de resíduos (LMR) estabelecido pela legislação brasileira (C2); a terceira equivalente ao limite de detecção declarado pelo fabricante (C3); e a quarta equivalente ao dobro do limite de detecção declarado pelo fabricante (C4). Os testes apresentaram 100% de sensibilidade na detecção de amoxicilina, ampicilina, cloxacilina, penicilina, tilosina, sulfadiazina, sulfametoxazol, e 96,7% na detecção de oxacilina para as concentrações informadas pelo fabricante como limite de detecção. Em relação às concentrações estabelecidas pela legislação brasileira, verificou-se que os testes foram capazes de detectá-las para a maioria dos antimicrobianos avaliados. Os testes não se mostraram eficientes na detecção das concentrações estabelecidas pela legislação para eritromicina, oxitetraciclina, tetraciclina, trimetoprim e gentamicina (Microplate).<br>The efficacy of the microbiological kits COPAN (Microplate and Single) for detection of antimicrobials residues was tested. Thirteen drugs were inoculated into milk without residues at four concentration levels: C1 - half of the detection threshold declared by the manufacturer, C2 - the maximum residues threshold established by the Brazilian legislation, C3 - the detection threshold declared by the manufacturer, and C4 - two fold the detection threshold declared by the manufacturer. The tests showed 100% efficient in detection of amoxicillin, cloxacillin, penicillin, tilosin, sulfadiazine, and sulfa methoxazol; and 96.7% for oxacillin considering the concentration stated by the manufacturer as threshold level. Regarding the concentrations established by the Brazilian legislation, all tested kits were able to detect most of the evaluated antimicrobials. The kits were not efficient in detection of the concentration levels established by the Brazilian legislation for erythromycin, oxytetracyclin, tetracyclin, trimetoprim, and gentamycin (Microplate).

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. T. E. (2009). Eficiência dos testes COPAN (Microplate e Single) na detecção de resíduos de antimicrobianos no leite Efficacy of COPAN (Microplate and Single kits) in detection of antimicrobials residues in milk. https://doi.org/10.1590/S0102-09352009000200031

MLA

al, C.G.M.S.C. Tenório et. "Eficiência dos testes COPAN (Microplate e Single) na detecção de resíduos de antimicrobianos no leite Efficacy of COPAN (Microplate and Single kits) in detection of antimicrobials residues in milk." 2009. https://doi.org/10.1590/S0102-09352009000200031.

Chicago

al, C.G.M.S.C. Tenório et. 2009. "Eficiência dos testes COPAN (Microplate e Single) na detecção de resíduos de antimicrobianos no leite Efficacy of COPAN (Microplate and Single kits) in detection of antimicrobials residues in milk.". https://doi.org/10.1590/S0102-09352009000200031.

Harvard

al, C. T. E. 2009, Eficiência dos testes COPAN (Microplate e Single) na detecção de resíduos de antimicrobianos no leite Efficacy of COPAN (Microplate and Single kits) in detection of antimicrobials residues in milk, Universidade Federal de Minas Gerais, Escola de Veterinária, available at: https://doi.org/10.1590/S0102-09352009000200031 [Accessed 6 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Eficiência dos testes COPAN (Microplate e Single) na detecção de resíduos de antimicrobianos no leite Efficacy of COPAN (Microplate and Single kits) in detection of antimicrobials residues in milk
Author / contributors
C.G.M.S.C. Tenório et al
Publisher
Universidade Federal de Minas Gerais, Escola de Veterinária
Publication year
2009
ISSN
0102-0935
ISSN
0102-0935
Language
English

Subjects

Explore related resources through these subjects.

Copied