Back to results
Bibliographic record · Consultation and access
Artículo

Workspace and Accuracy Analysis on a Novel 6-UCU Bone-attached Parallel Manipulator

Kaijie Dong et al · KeAi Communications Co., Ltd · 2022

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract With the increasingly more extensive application of the medical surgical robot in the clinic, higher requirements have been put forward for medical robots. The bone-attached robot, a popular orthopedic robot in recent years, has a tendency of miniaturization and refinement. Thus, a bone-attached parallel manipulator (PM) based on 6-UCU (universal-cylindrical-universal) configuration is proposed, which is characterized by small volume, compact structure, high precision and six-dimensional force feedback. To optimize the structure and make it more compact, the workspace of the 6-UCU PM is analyzed based on the analysis of three kinds of constraint, and workspace model is established through spherical coordinate search method. This study also analyzes the influence of structural parameters on workspace, which may contribute to improving the efficiency of design and ensuring small-sized robots possess relatively large workspace. Moreover, to improve the motion accuracy, an error modeling method is developed based on the structure of 6-UCU PMs. According to this established error model, the output pose error curves are drawn using MATLAB software when the structure parameters change, and the influence of the structure and pose parameters change on the output pose error of PMs is analyzed. The proposed research provides the instruction to design and analysis of small PMs such as bone-attached robots.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, K. D. E. (2022). Workspace and Accuracy Analysis on a Novel 6-UCU Bone-attached Parallel Manipulator. https://doi.org/10.1186/s10033-022-00689-1

MLA

al, Kaijie Dong et. "Workspace and Accuracy Analysis on a Novel 6-UCU Bone-attached Parallel Manipulator." 2022. https://doi.org/10.1186/s10033-022-00689-1.

Chicago

al, Kaijie Dong et. 2022. "Workspace and Accuracy Analysis on a Novel 6-UCU Bone-attached Parallel Manipulator.". https://doi.org/10.1186/s10033-022-00689-1.

Harvard

al, K. D. E. 2022, Workspace and Accuracy Analysis on a Novel 6-UCU Bone-attached Parallel Manipulator, KeAi Communications Co, Ltd, available at: https://doi.org/10.1186/s10033-022-00689-1 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Workspace and Accuracy Analysis on a Novel 6-UCU Bone-attached Parallel Manipulator
Author / contributors
Kaijie Dong et al
Publisher
KeAi Communications Co., Ltd
Publication year
2022
ISSN
1000-9345
ISSN
1000-9345
Language
English

Subjects

Explore related resources through these subjects.

Copied