Back to results
Bibliographic record · Consultation and access
Artículo de revista

Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%

Stacey Ness et al · Rockefeller University Press · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A 5-Year-Old Female with Neutropenia and Compound Heterozygous Variants in CXCR2

This serial publication contains 232 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

IntroductionIt is imperative to minimize protein aggregates in commercial intravenous immunoglobulin (IVIG) therapy as they have been implicated in adverse events and can enhance immunogenicity for patients receiving IVIG therapy. Shear stress, agitation, mixing speed, and filtration can impact aggregate formation during the manufacturing process, while shipping conditions and temperature excursions may contribute after manufacturing. A study was conducted to assess the impact of agitation on the molecular size distribution of Alyglo (immune globulin intravenous, human-stwk, 10% [IVIG-stwk 10%]).Methods10 mL of IVIG-stwk 10% was dispensed into sterile washed vials, which were stoppered and sealed. Vials were then placed on a Green SSeriker shaker (Vision Science), and agitation started at 50 rpm in an upright position at a temperature of between 20 and 25°C to induce mechanical stress. On days 0, 1, 3, and 11, samples were withdrawn and diluted 1:16 with saline for analysis. The molecular size distribution of monomers, dimers, high-molecular weight aggregates, and fragments was quantified using size-exclusion high-performance liquid chromatography (SE-HPLC). For SE-HPLC, chromatographic separations were performed using a size exclusion column (TSKgel G3000SW) using a sample size of 50 mcL and a flow rate of 0.5 mL/min at a detection wavelength of 280 nm.ResultsThe monomer + dimer percentage for IVIG-stwk 10% on day 0 was 99.576%; day 1 99.582%; day 3 99.591%; day 11 99.526%. The percentage of polymers and fragments remained below their respective validated limits of quantitation (0.3% and 0.5%) for each time point.ConclusionMechanical agitation for up to 11 days shows minimal impact on IVIG-stwk 10% molecular size distribution. A very high percentage of monomers and dimers remained throughout the duration of the study, compared to polymers and fragments below quantifiable limits. Further assessments, more analogous to real-world conditions, along with additional measurements of opacity and particle size across multiple lots to assess variability, are warranted.Tabular data are included as downloadable supplement files.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. N. E. (2026). Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%. https://doi.org/10.70962/CIS2026abstract.58

MLA

al, Stacey Ness et. "Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%." 2026. https://doi.org/10.70962/CIS2026abstract.58.

Chicago

al, Stacey Ness et. 2026. "Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%.". https://doi.org/10.70962/CIS2026abstract.58.

Harvard

al, S. N. E. 2026, Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%, Rockefeller University Press, available at: https://doi.org/10.70962/CIS2026abstract.58 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Foundational Analysis of the Impact of Mechanical Stress on Molecular Size Distribution in Immune Globulin Intravenous, Human-stwk, 10%
Author / contributors
Stacey Ness et al
Publisher
Rockefeller University Press
Publication year
2026
ISSN
3065-8993
ISSN
3065-8993
Language
English
Copied