Back to results
Bibliographic record · Consultation and access
Artículo de revista

Analysis and Design of High-Frequency CC/CV ZVS WPT System Without Any Feedback From Receiver to Transmitter

Ayano Komanaka et al · IEEE · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

3PS-RAN: A Real-Time Framework for Securing the O-RAN RACH Against DDoS Attacks Toward NextG

This serial publication contains 172 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

This paper proposes a high-frequency wireless power transfer (WPT) system. This system achieves zero-voltage switching (ZVS) and the constant current (CC) and constant voltage (CV) outputs regardless of load variations and coil misalignment. Furthermore, this system does not require feedback wireless communication from the receiver to the transmitter. Analytical expressions of the class-E inverter for achieving the ZVS against load variations without any control are given. By using the class-E ZVS inverter as a transmitter and complete resonance of the compensation circuits of the receiver in combination, the ZVS and CC/CV achievements become independent problems. Additionally, the proposed WPT system does not need wireless communication for information feedback. As a result, the proposed system achieves ZVS and CC/CV output switching against load variations and coil misalignments without any feedback. Experimental results agreed with the analytical predictions. Namely, the ZVS and the specified output current or voltage could be achieved against load variations and coil misalignments, which demonstrated the validity and effectiveness of the proposed system and its analysis. In the experiment, the maximum value of the power delivery efficiency was 87.2 % with the transmission frequency of 6.78 MHz and the output power of 50.7 W.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. K. E. (2026). Analysis and Design of High-Frequency CC/CV ZVS WPT System Without Any Feedback From Receiver to Transmitter. https://doi.org/10.1109/ACCESS.2026.3683361

MLA

al, Ayano Komanaka et. "Analysis and Design of High-Frequency CC/CV ZVS WPT System Without Any Feedback From Receiver to Transmitter." 2026. https://doi.org/10.1109/ACCESS.2026.3683361.

Chicago

al, Ayano Komanaka et. 2026. "Analysis and Design of High-Frequency CC/CV ZVS WPT System Without Any Feedback From Receiver to Transmitter.". https://doi.org/10.1109/ACCESS.2026.3683361.

Harvard

al, A. K. E. 2026, Analysis and Design of High-Frequency CC/CV ZVS WPT System Without Any Feedback From Receiver to Transmitter, IEEE, available at: https://doi.org/10.1109/ACCESS.2026.3683361 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Analysis and Design of High-Frequency CC/CV ZVS WPT System Without Any Feedback From Receiver to Transmitter
Author / contributors
Ayano Komanaka et al
Publisher
IEEE
Publication year
2026
ISSN
2169-3536
ISSN
2169-3536
Language
English

Subjects

Explore related resources through these subjects.

Copied