Back to results
Bibliographic record · Consultation and access
Artículo

Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure

Preston Harrison BS et al · SAGE Publishing · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Category: Midfoot/Forefoot, Bunion Diabetes Keywords: Ankle, Degenerative, Hindfoot Deformity Introduction/Purpose: Intraoperative fluoroscopy has become essential in orthopedic surgery, particularly with the rise of minimally invasive surgery (MIS) techniques. Despite the advantages of minimally invasive foot and ankle surgery, it raises concerns about radiation exposure to both patients and surgical staff. The purpose of this study was to evaluate fluoroscopy time and radiation dose (cumulative air kerma) associated with open versus MIS bunion correction, comparing the open modified Lapidus procedure and the minimally invasive distal first metatarsal transverse osteotomy and akin osteotomy (META). It was hypothesized that the META procedure would be associated with increased radiation dose and fluoroscopy time compared to the open modified Lapidus procedure. Methods: A retrospective review was conducted for patients who underwent bunion surgery between January 2021 and June 2025 by two fellowship-trained orthopedic foot and ankle surgeons at a single academic institution. A total of 294 patients met inclusion criteria. Of these, 258 patients underwent a META procedure and 36 underwent an open modified Lapidus procedure. Fluoroscopy time (minutes) and radiation dose (mGy) were compared between groups. Results: A mean fluoroscopy time of 2.13±1.27 (range, 0.06-7.05) minutes and a radiation dose of 2.02±1.30 (range, 0.05-7.52) mGy were observed in the META cohort. An average fluoroscopy time of 1.63±1.83 (range, 0.08-7.70) minutes and a radiation dose of 1.31±1.43 (range, 0.07-5.98) mGy were observed in the open modified Lapidus cohort. There was no significant difference in fluoroscopy time between cohorts (p=0.123), however the META group demonstrated a higher radiation dose than the open modified Lapidus group (p=0.007). Conclusion: The META procedure had a significantly higher radiation dose compared to the open modified Lapidus procedure, though both remain substantially below the International Commission on Radiological Protection (ICRP) recommended occupational exposure of less than 20.00 mSv per year. Despite the META procedure generating an average radiation dose of 2.02 mGy per case, surgeons receive only 0.50% of the dose, thus, nearly 1,980 procedures would be required to exceed the 20.00 mSv annual occupational limit. These findings suggest that concerns about radiation exposure should not necessarily deter providers from performing the META technique for bunion correction.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, P. H. B. E. (2026). Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure. https://doi.org/10.1177/2473011426S00047

MLA

al, Preston Harrison BS et. "Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure." 2026. https://doi.org/10.1177/2473011426S00047.

Chicago

al, Preston Harrison BS et. 2026. "Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure.". https://doi.org/10.1177/2473011426S00047.

Harvard

al, P. H. B. E. 2026, Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure, SAGE Publishing, available at: https://doi.org/10.1177/2473011426S00047 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure
Author / contributors
Preston Harrison BS et al
Publisher
SAGE Publishing
Publication year
2026
ISSN
2473-0114
ISSN
2473-0114
Language
English
Copied