Back to results
Bibliographic record · Consultation and access
Artículo

Research on burnout fault analysis of disassembly smart electricity meter and corresponding strategy

HUANG Hongqiao et al · Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

The number of disassembly smart electricity meters caused by the reincarnation, replacement, failure, and demolition of electricity meters has increased dramatically, and it is of great significance to analyze the faults of disassembly smart electricity meters to reuse and improve the reliability of disassembly smart electricity meter. Based on the fault data of disassembly smart electricity meter in a province, this paper analyzes and summarizes the internal and external influencing factors of disassembly smart electricity meter faults. The correlation analysis is used to carry out the correlation analysis of fault historical data. Combined with meteorological, historical calibration and re-calibration data, it is analyzed and clear that the non-compliance of the wire process and the non-compliance of the wiring material are the main reasons for the burnout meters. The strategy of improving the reliability of smart electricity meters is proposed to improve the quality of on-site assembly and copper-aluminum transition joints, and the measured data are compared and analyzed. The results show that after applying the proposed strategy, the burnout rate of smart electricity meters decreases from 82.73% to 34.55%, and the burnout rate of live wire terminals decreases from 81.44% to 35.01%, which not only directly reduces the burnout rate of low-voltage stations in the province, but also effectively improves the installation and operation and maintenance standardization of metering assets.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. H. E. (2026). Research on burnout fault analysis of disassembly smart electricity meter and corresponding strategy. https://doi.org/10.19753/j.issn1001-1390.2026.03.019

MLA

al, HUANG Hongqiao et. "Research on burnout fault analysis of disassembly smart electricity meter and corresponding strategy." 2026. https://doi.org/10.19753/j.issn1001-1390.2026.03.019.

Chicago

al, HUANG Hongqiao et. 2026. "Research on burnout fault analysis of disassembly smart electricity meter and corresponding strategy.". https://doi.org/10.19753/j.issn1001-1390.2026.03.019.

Harvard

al, H. H. E. 2026, Research on burnout fault analysis of disassembly smart electricity meter and corresponding strategy, Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co, Ltd, available at: https://doi.org/10.19753/j.issn1001-1390.2026.03.019 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Research on burnout fault analysis of disassembly smart electricity meter and corresponding strategy
Author / contributors
HUANG Hongqiao et al
Publisher
Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd
Publication year
2026
ISSN
1001-1390
ISSN
1001-1390
Language
zho

Subjects

Explore related resources through these subjects.

Copied