Back to results
Bibliographic record · Consultation and access
Artículo

Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk

PEI Maolin et al · Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Direct-drive wind farms usually trip all wind turbines to ensure power grid security when facing sub/super-synchronous oscillation risks. Tripping the entire wind farm not only seriously damages the production operation of the wind farm, but also causes a large impact on the power grid, which is an emergency measure that has to be taken after the situation escalates. To address this problem, this paper proposes a wide-frequency measurement device assisted power regulation and generator tripping control strategy for direct-drive wind farms, to achieve early warning and rapid suppression of sub/super-synchronous oscillation accidents. The wind farm pays attention to events such as lightning tripping in the regional power grid that may induce oscillations at any time. When receiving an event report, the wind farm immediately enters a pre-warning state and adjusts the power of each wind turbine according to the pre-action strategy to enter a low-inducing state, while the wide-frequency measurement device enters an emergency state to monitor whether the wind farm has sub/super-synchronous oscillations. When oscillations are detected, the wind farm defines the tripping intensity index according to the distance between each wind turbine and the grid-connected point and the power of each wind turbine, and executes the tripping strategy for some wind turbines to achieve oscillation elimination. This paper establishes relevant simulation examples to verify the feasibility and effectiveness of the control strategy. The simulation results show that the proposed power regulation and generator tripping control strategy achieves the suppression of oscillations in direct-drive wind farms, while avoiding the tripping of all wind turbines in the wind farm, reducing the impact on the power grid.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, P. M. E. (2026). Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk. https://doi.org/10.19753/j.issn1001-1390.2026.03.014

MLA

al, PEI Maolin et. "Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk." 2026. https://doi.org/10.19753/j.issn1001-1390.2026.03.014.

Chicago

al, PEI Maolin et. 2026. "Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk.". https://doi.org/10.19753/j.issn1001-1390.2026.03.014.

Harvard

al, P. M. E. 2026, Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk, Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co, Ltd, available at: https://doi.org/10.19753/j.issn1001-1390.2026.03.014 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Power regulation and generator tripping control strategy for direct-drive wind farms under sub/super-synchronous oscillation risk
Author / contributors
PEI Maolin et al
Publisher
Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd
Publication year
2026
ISSN
1001-1390
ISSN
1001-1390
Language
zho

Subjects

Explore related resources through these subjects.

Copied