Back to results
Bibliographic record · Consultation and access
Artículo

Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network

HE Jianbo et al · Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

The occurrence of tree-contact single-phase-to-ground fault (TSF) poses a potential threat to the stable operation of power lines, and in severe cases, may result in wild fire. The development of TSF is influenced by crucial factors such as temperature and moisture content; however, the precise process and mechanism through which they impact failure remain unclear. This paper takes naturally growing pine trees as the experimental object and conducts a TSF experimental study. Based on the experimental data, it analyzes the impact of temperature and tree moisture content on the transition resistance of trees during TSF, and establishes an equivalent model of TSF transition resistance that takes into account the temperature and the moisture content of trees. The average relative error between model prediction and experimental measurement is less than 10%, validating the effectiveness of the model. The results show that the current heating of TSF will cause the water vapor inside the branches to evaporate into the interlayer between the bark and the trunk, which in turn affects the leakage current flow path and forms a carbonization channel on the interlayer. The distribution of moisture content caused by local heating and water vapor evaporation in the current channel is the main factor affecting the leakage current and transition resistance changes of TSF. The refined model diminishes its reliance on traditional empirical parameters and boasts enhanced alignment with experimental measurement data, offering valuable insight into the mechanisms underlying fault progression.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. J. E. (2026). Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network. https://doi.org/10.19753/j.issn1001-1390.2026.03.011

MLA

al, HE Jianbo et. "Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network." 2026. https://doi.org/10.19753/j.issn1001-1390.2026.03.011.

Chicago

al, HE Jianbo et. 2026. "Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network.". https://doi.org/10.19753/j.issn1001-1390.2026.03.011.

Harvard

al, H. J. E. 2026, Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network, Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co, Ltd, available at: https://doi.org/10.19753/j.issn1001-1390.2026.03.011 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Impact of temperature and tree moisture content on evolution characteristics of transition resistance of tree-contact single-phase-to-ground fault in distribution network
Author / contributors
HE Jianbo et al
Publisher
Harbin Jinhe Electrical Measurement & Instrumentation Magazine Publishing Co., Ltd
Publication year
2026
ISSN
1001-1390
ISSN
1001-1390
Language
zho

Subjects

Explore related resources through these subjects.

Copied