Back to results
Bibliographic record · Consultation and access
Artículo

Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise

Antoine Ferrari et al · Frontiers Media S.A · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

IntroductionSweating is essential for thermoregulation during exercise but causes variable losses of water and sodium chloride (NaCl). Field-based methods to assess these losses are limited by sampling errors and the lack of real-time feedback. This study evaluated the validity and reliability of the BeOne armband for continuous measurement of sweat conductivity, used to estimate sweat [NaCl] equivalent in real time.MethodsTen armbands were first tested against standard NaCl solutions (5–120 mmol·L−1) to assess the validity of the conductivity measurement. Reliability was then examined in sixteen men who completed two 60-min cycling sessions at 150 W in temperate condition (24 ± 1 °C; 50 ± 10% RH) while wearing armbands on both forearms. Outcomes included sweat onset (defined as the time from exercise onset to first detection of sweat conductivity), sweat [NaCl] equivalent drift, and time-normalized [NaCl] equivalent kinetics.ResultsMeasured values showed minimal bias (0.28 mmol·L−1, 95% LoA: –1.21 to 1.77), very low CVs (0.5–2.6%), and excellent inter-device agreement (ICC = 1.00) for conductivity measurements. During exercise, sweat onset did not differ between arms or sessions, but showed moderate within-session (ICC = 0.72) and low between-session reliability (ICC = 0.29), indicating substantial day-to-day variability of this specific index. Drift indices and time-normalized [NaCl] equivalent kinetics revealed a reproducible temporal profile, characterized by an initial peak, a rapid decline, a gradual increase, and a plateau toward the end of exercise.ConclusionThe BeOne armband demonstrated excellent analytical validity for sweat conductivity measurement and reliable within-session characterization of conductivity-derived sweat electrolyte dynamics. Although conductivity-based [NaCl] equivalents do not represent a laboratory gold standard and remain sensitive to matrix effects and non-specific ionic contributions, this approach appears sufficiently robust for applied sport-science contexts requiring continuous monitoring.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. F. E. (2026). Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise. https://doi.org/10.3389/fphys.2026.1809119

MLA

al, Antoine Ferrari et. "Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise." 2026. https://doi.org/10.3389/fphys.2026.1809119.

Chicago

al, Antoine Ferrari et. 2026. "Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise.". https://doi.org/10.3389/fphys.2026.1809119.

Harvard

al, A. F. E. 2026, Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise, Frontiers Media S.A, available at: https://doi.org/10.3389/fphys.2026.1809119 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Validity and reliability of a wearable armband for continuous sweat conductivity monitoring during exercise
Author / contributors
Antoine Ferrari et al
Publisher
Frontiers Media S.A
Publication year
2026
ISSN
1664-042X
ISSN
1664-042X
Language
English

Subjects

Explore related resources through these subjects.

Copied