Back to results
Bibliographic record · Consultation and access
Artículo

Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria

Mmatlou D. Seema et al · AOSIS · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Background: The rising demand for interventional radiology procedures (IRPs) performed under fluoroscopic guidance increases the risk of harmful radiation effects for patients and staff. Radiation dose optimisation using diagnostic reference levels (DRLs) is necessary to keep radiation ‘as low as reasonably achievable (ALARA)’. Establishment of DRLs is required for radiation imaging centres; however, only a few have published them in South Africa. This study aimed to establish local diagnostic reference levels (LDRLs) for IRPs and compare them with DRLs of local and international imaging centres. Methods: A retrospective descriptive study was conducted at a single imaging centre. The IRPs performed on adults between 01 January 2023 and 31 December 2023 were considered. Ethical clearance was obtained before data collection. Data on fluoroscopy time (FT) and kerma air product (KAP) were obtained from a procedure register book. The third quartile (75th percentile) of the dataset for KAP and FT of every IRP indicated the LDRLs. Results: A total of 375 IRPs were analysed. The most frequently performed IRP was cerebral interventions (21%, n = 80). Aortic interventions recorded the highest dose LDRL (KAP = 252.5 Gy/cm2), followed by cerebral interventions (KAP = 211.3 Gy/cm2). Cerebral interventions recorded the longest FT (56.8 min), followed by aortic interventions (36.2 min), both of which exceeded the local centres’ DRL ranges. Permanent catheterisation (KAP = 10.7 Gy/cm2) also exceeded the international DRL range. Conclusion: Established LDRLs for IRPs were mostly within local and international DRL ranges. Contribution: The study contributed to the establishment of local, national and regional DRLs, which assisted imaging centres in optimising radiation doses for IRPs.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. D. S. E. (2026). Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria. https://doi.org/10.4102/jcmsa.v4i1.279

MLA

al, Mmatlou D. Seema et. "Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria." 2026. https://doi.org/10.4102/jcmsa.v4i1.279.

Chicago

al, Mmatlou D. Seema et. 2026. "Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria.". https://doi.org/10.4102/jcmsa.v4i1.279.

Harvard

al, M. D. S. E. 2026, Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria, AOSIS, available at: https://doi.org/10.4102/jcmsa.v4i1.279 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Patient radiation doses in an angiography suite at a tertiary hospital in Pretoria
Author / contributors
Mmatlou D. Seema et al
Publisher
AOSIS
Publication year
2026
ISSN
3105-4331
ISSN
3105-4331
Language
English

Subjects

Explore related resources through these subjects.

Copied