Back to results
Bibliographic record · Consultation and access
Artículo de revista

Assessment of Clinical Hematology Laboratory Performance Using Sigma Metrics and Associated Factors in Total Testing Process at the Dessie Comprehensive Specialized Hospital, Northeast, Ethiopia: A Cross‐Sectional Study

Zewudu Mulatie et al · Wiley · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A Comparative Study on Hypochondriasis Among Medical and Dental Students in Post‐COVID‐19 Pandemic: A Cross‐Sectional Study

This serial publication contains 222 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

ABSTRACT Background and Aims Clinical laboratory test results play a fundamental role in clinical decision making, influencing approximately 70% of medical decisions. Numerous studies have shown that errors can occur throughout the total testing process. This study aimed to assess the performance of the Clinical Hematology Laboratory and identify associated factors using sigma metrics across the total testing process at Dessie Comprehensive Specialized Hospital. Methods A cross‐sectional study was conducted from July1, 2023, to September 30, 2023. The study included all eligible laboratory samples and corresponding test requests during the study period using a consecutive sampling technique. Data for each variable were collected using a pre prepared checklist and record formats by trained laboratory professionals. The data were entered into EPI data version 3.1 and exported to Stata version 17 for analysis. Logistic regression analysis was performed, and the laboratory's total testing process performance was evaluated using the sigma scale. Result The overall prevalence of clinical hematology laboratory errors in the total testing process was 12.44%. Most errors occurred during the pre‐analytical phase (77.8%), followed by the post‐analytical phase (19.77%) and the analytical phase (2.36%). The overall sigma value of the hematology laboratory was 2.7, indicating substandard performance. The sigma values for the pre‐analytical, analytical, and post‐analytical phases were 2.6, 3.2, and 2.8, respectively. Conclusion and Recommendation This study found that errors in the clinical hematology laboratory were common, and overall performance was below the acceptable sigma threshold. Therefore, hospital administration should provide need‐based training for all staff involved in hematology laboratory sample collection and processing. Strengthening adherence to standard operating procedures and implementing continuous quality improvement strategies are essential to enhance laboratory performance and reduce errors.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Z. M. E. (2026). Assessment of Clinical Hematology Laboratory Performance Using Sigma Metrics and Associated Factors in Total Testing Process at the Dessie Comprehensive Specialized Hospital, Northeast, Ethiopia: A Cross‐Sectional Study. https://doi.org/10.1002/hsr2.72063

MLA

al, Zewudu Mulatie et. "Assessment of Clinical Hematology Laboratory Performance Using Sigma Metrics and Associated Factors in Total Testing Process at the Dessie Comprehensive Specialized Hospital, Northeast, Ethiopia: A Cross‐Sectional Study." 2026. https://doi.org/10.1002/hsr2.72063.

Chicago

al, Zewudu Mulatie et. 2026. "Assessment of Clinical Hematology Laboratory Performance Using Sigma Metrics and Associated Factors in Total Testing Process at the Dessie Comprehensive Specialized Hospital, Northeast, Ethiopia: A Cross‐Sectional Study.". https://doi.org/10.1002/hsr2.72063.

Harvard

al, Z. M. E. 2026, Assessment of Clinical Hematology Laboratory Performance Using Sigma Metrics and Associated Factors in Total Testing Process at the Dessie Comprehensive Specialized Hospital, Northeast, Ethiopia: A Cross‐Sectional Study, Wiley, available at: https://doi.org/10.1002/hsr2.72063 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Assessment of Clinical Hematology Laboratory Performance Using Sigma Metrics and Associated Factors in Total Testing Process at the Dessie Comprehensive Specialized Hospital, Northeast, Ethiopia: A Cross‐Sectional Study
Author / contributors
Zewudu Mulatie et al
Publisher
Wiley
Publication year
2026
ISSN
2398-8835
ISSN
2398-8835
Language
English

Subjects

Explore related resources through these subjects.

Copied