Back to results
Bibliographic record · Consultation and access
Artículo

Construction and validation of a prediction model for in-stent restenosis following coronary stent implantation during dual antiplatelet therapy

Zhuoyi Zhang et al · Frontiers Media S.A · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

ObjectivesIn-stent restenosis (ISR) is a serious complication that occurs after a percutaneous coronary intervention (PCI). This study aims to integrate thromboelastography (TEG) parameters, coagulation function, and clinical indicators to develop and validate a prediction model for ISR during antiplatelet therapy after PCI.MethodA total of 401 consecutive patients with coronary artery disease who underwent a PCI with drug-eluting stent implantation between January 2018 and January 2024 were enrolled in this study. Clinical baseline characteristics were collected. The Least Absolute Shrinkage and Selection Operator (LASSO) regression was used to screen 6 key predictors from 34 candidate clinical features. Multivariate logistic regression identified independent risk factors for ISR. Model performance was evaluated using the receiver operating characteristic curve for discrimination, bootstrap internal validation for stability, the Hosmer–Lemeshow test for goodness of fit, and decision curve analysis for clinical utility.ResultsAmong the 401 enrolled patients, 137 (34.2%) developed ISR. LASSO regression selected 6 key predictors from 34 candidate variables. Multivariable logistic regression ultimately identified a low adenosine diphosphate (ADP) inhibition rate, a low arachidonic acid (AA) inhibition rate, reaction time (R-value), and age as independent risk factors for ISR. The constructed nomogram demonstrated good discrimination (area under the curve = 0.752, 95% confidence interval: 0.702–0.803), stable performance upon bootstrap internal validation, and satisfactory calibration (Hosmer–Lemeshow test, P = 0.320). Furthermore, decision curve analysis indicated a favorable clinical net benefit across a broad range of threshold probabilities.ConclusionsThe prediction model, constructed based on TEG parameters (ADP inhibition rate, AA inhibition rate, R-value), age, and N-terminal pro-B-type natriuretic peptide, effectively identifies patients at high risk for ISR after a PCI. It provides a basis for individualized antiplatelet therapy and postoperative management decisions.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Z. Z. E. (2026). Construction and validation of a prediction model for in-stent restenosis following coronary stent implantation during dual antiplatelet therapy. https://doi.org/10.3389/fcvm.2026.1780572

MLA

al, Zhuoyi Zhang et. "Construction and validation of a prediction model for in-stent restenosis following coronary stent implantation during dual antiplatelet therapy." 2026. https://doi.org/10.3389/fcvm.2026.1780572.

Chicago

al, Zhuoyi Zhang et. 2026. "Construction and validation of a prediction model for in-stent restenosis following coronary stent implantation during dual antiplatelet therapy.". https://doi.org/10.3389/fcvm.2026.1780572.

Harvard

al, Z. Z. E. 2026, Construction and validation of a prediction model for in-stent restenosis following coronary stent implantation during dual antiplatelet therapy, Frontiers Media S.A, available at: https://doi.org/10.3389/fcvm.2026.1780572 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Construction and validation of a prediction model for in-stent restenosis following coronary stent implantation during dual antiplatelet therapy
Author / contributors
Zhuoyi Zhang et al
Publisher
Frontiers Media S.A
Publication year
2026
ISSN
2297-055X
ISSN
2297-055X
Language
English

Subjects

Explore related resources through these subjects.

Copied