Back to results
Bibliographic record · Consultation and access
Artículo

Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial

Wonhyeong Lee et al · Elsevier · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Background and purpose: A dummy run quality assurance was conducted for a prospective phase II trial of tailored radiotherapy (RT) according to the response after neoadjuvant chemotherapy (NAC) followed by surgery in locally advanced breast cancer (RTaNAC). Since inter-institutional variations in dose distributions can impact clinical outcomes, this dummy run aimed to develop an RT plan protocol to minimize these variations. Material and methods: This study involved computed tomography images from three clinical scenarios: RT with no lymph node (LN) boost (Scenario 1), LN boost up to 60 Gy3.5, equivalent dose in 2 Gy fractions (EQD2) with α/β = 3.5 Gy (Scenario 2), and LN boost up to 66 Gy3.5 (Scenario 3). Seven institutions developed RT plans under a two-step process: first according to each institution’s policies (Step 1) and then using additional reference information, including artificial intelligence (AI) auto-contoured structures and LN boost target volume information (Step 2). Dose-volume histograms for breast and regional nodal areas were analyzed between the two steps. Results: Inter-institutional variation observed in Step 1 improved in Step 2 for breast and regional nodal areas. Specifically for Scenario 1, dose coverage for the nodal clinical target volumes of the axillary level I LN improved from 57.5% to 97.5% (p-value = 0.075), and that of the supraclavicular LN improved from 75.6% to 88.8% (p-value = 0.046). Conclusion: Variations in dose/volume metrics among institutions were mitigated by AI auto-contoured structures and LN boost target volume information. Through this dummy run, the participating institutions reached a consensus on an RT plan protocol to support multi-institutional expansion of RTaNAC.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, W. L. E. (2026). Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial. https://doi.org/10.1016/j.phro.2026.100949

MLA

al, Wonhyeong Lee et. "Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial." 2026. https://doi.org/10.1016/j.phro.2026.100949.

Chicago

al, Wonhyeong Lee et. 2026. "Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial.". https://doi.org/10.1016/j.phro.2026.100949.

Harvard

al, W. L. E. 2026, Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial, Elsevier, available at: https://doi.org/10.1016/j.phro.2026.100949 [Accessed 5 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Quality assurance incorporating artificial intelligence-generated reference contours in a phase II radiotherapy trial
Author / contributors
Wonhyeong Lee et al
Publisher
Elsevier
Publication year
2026
ISSN
2405-6316
ISSN
2405-6316
Language
English

Subjects

Explore related resources through these subjects.

Copied