Back to results
Bibliographic record · Consultation and access
Artículo

Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction

Oglat AA et al · Dove Medical Press · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material
Otras opciones de acceso Elegí el proveedor disponible para esta ficha.
Importación CSV DOAJ - Open Access Journals
Acceder por Importación CSV

Summary

Descripción general del contenido del recurso.

Ammar A Oglat,1 Suhaib Shdaifat,1 Mohannad Adel Sayah,2 Ahmed Abukonna,3 Wadah M Ali Khogali3 1Department of Medical Imaging, Faculty of Applied Medical Sciences, The Hashemite University, Zarqa, 13133, Jordan; 2Department of Radiography, Faculty of Allied Medical Sciences, Al-Hussein Bin Talal University, Ma’an, 71111, Jordan; 3College of Medical and Health Sciences, Liwa University, Abu Dhabi, United Arab EmiratesCorrespondence: Ammar A Oglat, Email ammara@hu.edu.joAbstract: Computed tomography (CT) contributes substantially to medical radiation exposure, making diagnostic reference levels (DRLs) essential for dose optimization and patient protection. This narrative review summarizes international CT DRL practices and examines the current status of DRL development in Jordan. Published studies and key guidance documents addressing adult and pediatric CT DRLs, including CTDIvol, dose-length product (DLP), and size-specific dose estimate (SSDE) where available, were reviewed to identify common implementation approaches, frequently used dose metrics, and evidence gaps relevant to Jordan. The reviewed literature shows marked inter-country variation in DRL methodology, updating cycles, and regulatory integration. In Jordan, available studies demonstrate useful local and multicenter data, but routine CT practice still lacks a unified national DRL framework. Reported Jordanian values also show inter-institutional variability, highlighting the need for standardized data collection, regular auditing, and coordinated national oversight. Establishing national DRLs based on transparent methodology and periodic revision would strengthen radiation protection, improve protocol consistency, and support safer CT practice in Jordan.Keywords: computed tomography, diagnostic reference levels, radiation protection, patient safety, Jordan

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, O. A. E. (2026). Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction. https://www.dovepress.com/computed-tomography-diagnostic-reference-levels-worldwide-and-in-jorda-peer-reviewed-fulltext-article-DHPS

MLA

al, Oglat AA et. "Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction." 2026. https://www.dovepress.com/computed-tomography-diagnostic-reference-levels-worldwide-and-in-jorda-peer-reviewed-fulltext-article-DHPS.

Chicago

al, Oglat AA et. 2026. "Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction.". https://www.dovepress.com/computed-tomography-diagnostic-reference-levels-worldwide-and-in-jorda-peer-reviewed-fulltext-article-DHPS.

Harvard

al, O. A. E. 2026, Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction, Dove Medical Press, available at: https://www.dovepress.com/computed-tomography-diagnostic-reference-levels-worldwide-and-in-jorda-peer-reviewed-fulltext-article-DHPS [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction
Author / contributors
Oglat AA et al
Publisher
Dove Medical Press
Publication year
2026
ISSN
1179-1365
ISSN
1179-1365
Language
English

Subjects

Explore related resources through these subjects.

Copied