Back to results
Bibliographic record · Consultation and access
Artículo

An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification

Chris Barnes et al · SpringerOpen · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Background We previously reported the first-in-human evaluation of 3-[18F]-fluoro-2,2-dimethylpropionic acid ([18F]FPIA) for imaging aberrant lipid metabolism and cancer detection. The first-generation semi-automated radiosynthesis of [18F]FPIA required HPLC purification to provide injection solution devoid of precursor (methyl 2,2-dimethyl-3-[(4-methylbenzenesulfonyl)oxy]propanoate), radioactive intermediate (methyl-3-([18F]fluoro)-2,2-dimethylpropanoate), and potential chemical impurities (tosic acid, 3-hydroxy-2,2-dimethylpropanoic acid and unlabelled FPIA). In readiness for global use of [18F]FPIA, we report a significant improvement to the GMP production through development of a fully-automated solid-phase extraction (SPE) purification method. Results We developed a fully-automated SPE purified radiosynthesis on FASTLab™ for GMP readiness that was translated to and validated on the Trasis AIO™ platform for routine clinical use. Purification of the radiotracer by SPE on both systems was achieved (> 98% radiochemical purity), increasing the radiochemical yield compared to the HPLC-based purification method. Non-decay-corrected radiochemical yields (RCY, n.d.c) were 30.3 ± 2.3% (n = 8) and 25.8 ± 6.6% (n = 46) on GE FASTlab™ and Trasis AIO™, respectively. Non-radioactive FPIA and other analytes determined by HPLC were below the limit of detection (< 1.0 µg/mL) from GE FASTlab™ and ≤ 1.2 µg/mL from Trasis AIO™. Conclusions The synthesis of [18F]FPIA was validated on the Trasis AIO™ platform for GMP production and is currently used to produce clinical doses for phase II clinical trials. Readiness for GMP validation was also demonstrated on GE FASTlab™ and can be adopted on other automated platforms.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, C. B. E. (2026). An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification. https://doi.org/10.1186/s41181-026-00440-4

MLA

al, Chris Barnes et. "An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification." 2026. https://doi.org/10.1186/s41181-026-00440-4.

Chicago

al, Chris Barnes et. 2026. "An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification.". https://doi.org/10.1186/s41181-026-00440-4.

Harvard

al, C. B. E. 2026, An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification, SpringerOpen, available at: https://doi.org/10.1186/s41181-026-00440-4 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
An improved fully-automated GMP radiosynthesis of [18F]fluoro-pivalic acid with solid-phase extraction purification
Author / contributors
Chris Barnes et al
Publisher
SpringerOpen
Publication year
2026
ISSN
2365-421X
ISSN
2365-421X
Language
English

Subjects

Explore related resources through these subjects.

Copied