Back to results
Bibliographic record · Consultation and access
Artículo

The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images

Hongyan Wang et al · BMC · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Objective To investigate whether virtual unenhanced (VUE) images generated from spectral CT using the rapid kVp switching technique can serve as a substitute for true unenhanced (TUE) images in the assessment of acute pancreatitis (AP). Methods This retrospective study included 90 patients diagnosed with AP according to the Revised Atlanta Classification who underwent unenhanced non-spectral CT scan and dual-phase spectral CT scans of the abdomen. VUE images for the arterial (AP-VUE) and venous phases (VP-VUE) were reconstructed using material decomposition techniques. Objective and subjective assessments were conducted on TUE, AP-VUE, and VP-VUE images. The objective evaluation included CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The subjective evaluation was performed by three readers independently and assessed image quality, lesion identification, severity grading of pancreatitis, and diagnostic confidence. Results CT attenuations differences between the TUE and VUE images were not significant for AP lesion (P = 0.110 (Pancreatitis) & 0.052 (Peripancreatic effusion)), with over 76.67% of anatomical regions showing differences within 10 HU. Compared with VP-VUE and AP-VUE images, TUE images demonstrated higher SNR and CNR overall. Diagnostic confidence scores were comparable across TUE, AP-VUE, and VP-VUE (confidence scores from 5(4, 5) to 5(5, 5), P from 0.439 to 1.000) and the diagnostic conclusions showed no significant differences as well (P > 0.05). The Balthazar CT grading system (A–E) demonstrated high concordance (Intraclass correlation coefficients > 0.8) across all image types, with no difference in AP severity assessment (P > 0.05). Conclusion The diagnostic value of VUE images in AP is comparable to that of TUE images, suggesting that VUE images can serve as an alternative to reduce radiation exposure.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, H. W. E. (2026). The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images. https://doi.org/10.1186/s12880-026-02361-9

MLA

al, Hongyan Wang et. "The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images." 2026. https://doi.org/10.1186/s12880-026-02361-9.

Chicago

al, Hongyan Wang et. 2026. "The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images.". https://doi.org/10.1186/s12880-026-02361-9.

Harvard

al, H. W. E. 2026, The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images, BMC, available at: https://doi.org/10.1186/s12880-026-02361-9 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
The diagnostic value of virtual unenhanced spectral CT images in acute pancreatitis: a comparison with true unenhanced images
Author / contributors
Hongyan Wang et al
Publisher
BMC
Publication year
2026
ISSN
1471-2342
ISSN
1471-2342
Language
English

Subjects

Explore related resources through these subjects.

Copied