Back to results
Bibliographic record · Consultation and access
Artículo

Development of ready-to-use tranexamic acid gauze as a hemostatic material for oral surgery: fabrication, hemostasis, and shelf-life

Taechana Sitthikornvanich et al · BMC · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Background Postoperative hemorrhage is one of the major complications of oral surgery. Conventional hemostatic methods, such as chair-side preparation of tranexamic acid (TXA)-soaked gauze or TXA mouthwash, often suffer from dosage variability and increased surgical time. This study aimed to develop a ready-to-use TXA gauze and to evaluate its fabrication process, hemostatic efficiency, and shelf-life stability. Methods Gauze samples containing TXA concentrations of 2.5% and 5% (w/v) were fabricated using a freeze-drying technique. Characterization was performed using field emission scanning electron microscope (FESEM) and fourier transform infrared spectroscopy (FTIR). The in vitro blood clotting time (BCT) and plasma recalcification time (PRT) were assessed using independent biological replicates from six healthy volunteers (n = 6). Biocompatibility was assessed via MTT assay on 3T3 fibroblasts. Shelf-life stability was monitored over 180 days under International Conference on Harmonisation (ICH) Zone IV conditions (30 °C/65% RH and 4 °C). Results The morphological and FTIR measurements confirmed that the gauze fibers were effectively coated with TXA. Meanwhile, the TXA impregnation did not significantly impact the gauze’s physical and biological properties. A burst release of the TXA was observed for the first 3 min, ensuring rapid clot stabilization. In vitro coagulation tests showed that the TXA gauze significantly reduced coagulation times, enhancing the hemostatic process. Similar to 5% TXA gauze, 2.5% TXA gauze had biocompatibility and hemostatic effectiveness. This finding shows that a lower dose (2.5% w/v) achieved hemostasis, maximizing cost-effectiveness and lowering drug toxicity. Stability tests over six months at various temperatures confirmed that the TXA gauze maintained its hemostatic efficacy without significant drug degradation. Conclusions The prefabricated TXA gauze is a promising material, especially for patients on anticoagulant therapy, with long-term stability and practical deployment potential in clinical settings.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, T. S. E. (2026). Development of ready-to-use tranexamic acid gauze as a hemostatic material for oral surgery: fabrication, hemostasis, and shelf-life. https://doi.org/10.1186/s12903-026-08136-6

MLA

al, Taechana Sitthikornvanich et. "Development of ready-to-use tranexamic acid gauze as a hemostatic material for oral surgery: fabrication, hemostasis, and shelf-life." 2026. https://doi.org/10.1186/s12903-026-08136-6.

Chicago

al, Taechana Sitthikornvanich et. 2026. "Development of ready-to-use tranexamic acid gauze as a hemostatic material for oral surgery: fabrication, hemostasis, and shelf-life.". https://doi.org/10.1186/s12903-026-08136-6.

Harvard

al, T. S. E. 2026, Development of ready-to-use tranexamic acid gauze as a hemostatic material for oral surgery: fabrication, hemostasis, and shelf-life, BMC, available at: https://doi.org/10.1186/s12903-026-08136-6 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Development of ready-to-use tranexamic acid gauze as a hemostatic material for oral surgery: fabrication, hemostasis, and shelf-life
Author / contributors
Taechana Sitthikornvanich et al
Publisher
BMC
Publication year
2026
ISSN
1472-6831
ISSN
1472-6831
Language
English

Subjects

Explore related resources through these subjects.

Copied