Back to results
Bibliographic record · Consultation and access
Artículo

Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis

Abdulaziz Gul et al · BMC · 2026

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Background Various designs of dental implants made of zirconium dioxide (zirconia) as an alternative to titanium implants are available as one-piece implant (OPI) or as bone-level or tissue-level two-piece implants (TPI) with either ceramic or titanium abutment screw types of implant-abutment connections. This study aimed to identify and quantify stress concentrations and levels across different zirconia implant designs under a quasi-static external load. Methods The study used a finite element analysis (FEA) simulation model, including five zirconia implant design models of OPI and bone-level and tissue-level TPI zirconia implants with either ceramic or titanium abutment screw, to calculate and locate maximum principal (σ1) and minimum principal (σ3) and equivalent (von Mises) stresses under 400N of quasi-static loading at a 30-degree angle within ISO14801:2016 geometry and boundary conditions. The FEA assumed linear elastic and isotropic material properties. Results OPI showed high stress concentrations at the implant body’s external thread above the specimen holder. TPIs showed similar maximum principal stress (σ1) areas in their implant body, while minimum principal stress (σ3) occurred in the implant–abutment interface at the abutment neck, and the corresponding area in the implant platform. The TPIs with ceramic screws exhibited the highest stresses at the screw–abutment interface. Conclusions Within the limitations of this study, under a static oblique load applied within the ISO 14801:2016 geometry condition, stress distributions differ between OPI and TPI. TPIs show lower stress within the implant body but higher stress transfer to the specimen holder compared with OPI. Tissue-level TPIs exhibit lower stress than bone-level designs, whereas stresses in the abutment and screw depend on screw design and material. TPIs with ceramic screws exhibit higher stress levels compared to titanium screw.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. G. E. (2026). Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis. https://doi.org/10.1186/s12903-026-08192-y

MLA

al, Abdulaziz Gul et. "Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis." 2026. https://doi.org/10.1186/s12903-026-08192-y.

Chicago

al, Abdulaziz Gul et. 2026. "Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis.". https://doi.org/10.1186/s12903-026-08192-y.

Harvard

al, A. G. E. 2026, Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis, BMC, available at: https://doi.org/10.1186/s12903-026-08192-y [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Stress evaluation in one-piece and bone- or tissue-level two-piece zirconia dental implants with ceramic or titanium abutment screws: a finite element analysis
Author / contributors
Abdulaziz Gul et al
Publisher
BMC
Publication year
2026
ISSN
1472-6831
ISSN
1472-6831
Language
English

Subjects

Explore related resources through these subjects.

Copied