Back to results
Bibliographic record · Consultation and access
Artículo

Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator

Deepak K. Shrestha et al · BMC · 2026

Institutional access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Institutional access available

El acceso puede requerir institución, suscripción, proxy, VPN o autenticación.
Open access

Summary

Descripción general del contenido del recurso.

Abstract Purpose Intraoperative radiotherapy (IORT) is designed to deliver a precise dose of ionizing radiation to a tumor or tumor bed after surgical resection. The IORT procedure can deliver targeted radiation to the tumor with increased normal tissue sparing, hence improving the efficacy of the procedure when nearby organs at risk (OAR) can be mobilized out of the field thus maximizing the therapeutic ratio. This report presents the institutional experience of establishing the IORT program, highlighting our workflow improvement, quality assurance (QA), and dosimetric practices. Methods The IntraOp® Mobetron® 2000 can be used to irradiate a target using megavoltage (MV) electron beams of energies 6 MeV, 9 MeV, and 12 MeV at a high dose rate of 1000 cGy/minute. Mayo Clinic Florida (MCF) has a dedicated and well-shielded QA suite adjacent to the operating room (OR) for both treatment preparation and daily QA purposes. The Mobetron is docked over the target assembly with the help of the autodocking software. The IORT workflow in the OR is assisted by the Mobility (IntraOp Medical Corp., Sunnyvale, CA) system which ensures safe and efficient maneuvering of the Mobetron. The treatment planning and beam control using the treatment console is done from inside the shielded QA room. Results Since its commissioning in 2016, 138 patients have been treated with IORT using the Mobetron ® 2000, at MCF. The efficacy of IORT has been utilized in the treatment of locally advanced and recurrent sites like pancreas, rectum, retroperitoneal sarcoma and some gynecologic cases. Conclusion A well-planned housing of the Mobetron, adjacent to the OR, and its timely upgrades has resulted in an efficient and safe IORT workflow.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, D. K. S. E. (2026). Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator. https://doi.org/10.1186/s13014-026-02831-y

MLA

al, Deepak K. Shrestha et. "Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator." 2026. https://doi.org/10.1186/s13014-026-02831-y.

Chicago

al, Deepak K. Shrestha et. 2026. "Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator.". https://doi.org/10.1186/s13014-026-02831-y.

Harvard

al, D. K. S. E. 2026, Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator, BMC, available at: https://doi.org/10.1186/s13014-026-02831-y [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Efficient clinical workflow for intraoperative electron radiation therapy with a mobile electron accelerator
Author / contributors
Deepak K. Shrestha et al
Publisher
BMC
Publication year
2026
ISSN
1748-717X
ISSN
1748-717X
Language
English
Copied