Back to results
Bibliographic record · Consultation and access
Artículo

Fiber-optic Fabry–Pérot interferometric accelerometer with composite cavity and temperature calibration for high-temperature and high-pressure applications

Feng Qin et al · Nature Publishing Group · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract To address the demand for flow-induced vibration monitoring of steam generator heat transfer tubes in pressurized water reactors under high-temperature (350 °C) and high-pressure (17.5 MPa) conditions, a fiber-optic Fabry–Pérot interferometric accelerometer based on a composite Fabry–Pérot cavity structure is proposed. The sensor employs a symmetrically arranged multidirectional cantilever beam and a central proof mass to effectively reduce cross-axis sensitivity. Using a MEMS-based fabrication process, a three-layer sensing chip with a composite cavity is formed, mitigating the temperature drift problem of conventional single-cavity structures under elevated temperatures. A temperature calibration model is further incorporated to improve measurement accuracy. The optical path is folded by a 45° metallic mirror and hermetically sealed by laser welding, ensuring stable operation under high temperature, high pressure, and external mechanical shocks. Experimental results show that the sensor achieves a sensitivity of 4.53 nm/g, a resonant frequency of 7450 Hz, a cross-axis sensitivity as low as 0.281%, and a resolution of 4.4 mg, with an acceleration measurement range of ±238 g at room temperature. Under 350 °C and 17.5 MPa, the sensor exhibited cavity length drift below 0.1 nm during a 60-h stability test, demonstrating reliable dynamic performance and long-term stability in extreme conditions, which provides an effective tool for the continuous safety monitoring of critical heat transfer structures in pressurized water reactors.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, F. Q. E. (2026). Fiber-optic Fabry–Pérot interferometric accelerometer with composite cavity and temperature calibration for high-temperature and high-pressure applications. https://doi.org/10.1038/s41378-026-01250-z

MLA

al, Feng Qin et. "Fiber-optic Fabry–Pérot interferometric accelerometer with composite cavity and temperature calibration for high-temperature and high-pressure applications." 2026. https://doi.org/10.1038/s41378-026-01250-z.

Chicago

al, Feng Qin et. 2026. "Fiber-optic Fabry–Pérot interferometric accelerometer with composite cavity and temperature calibration for high-temperature and high-pressure applications.". https://doi.org/10.1038/s41378-026-01250-z.

Harvard

al, F. Q. E. 2026, Fiber-optic Fabry–Pérot interferometric accelerometer with composite cavity and temperature calibration for high-temperature and high-pressure applications, Nature Publishing Group, available at: https://doi.org/10.1038/s41378-026-01250-z [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Fiber-optic Fabry–Pérot interferometric accelerometer with composite cavity and temperature calibration for high-temperature and high-pressure applications
Author / contributors
Feng Qin et al
Publisher
Nature Publishing Group
Publication year
2026
ISSN
2055-7434
ISSN
2055-7434
Language
English
Copied