Back to results
Bibliographic record · Consultation and access
Artículo

CIRCLE-F/V: a dual-mode CRISPR-Cas13a cascade biosensor for ultrasensitive and visual detection of low-abundance EGFR mutations

Tao Zhu et al · BMC · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Precise identification of low-frequency EGFR L858R mutations is crucial for targeted therapy and prognosis in non-small cell lung cancer (NSCLC). Here, we present CIRCLE-F/V (CRISPR-based Integrated Restriction-assisted Cyclic Loop-mediated Enhancement Fluorescence/Visual platform), a dual-mode CRISPR-Cas13a cascade biosensor enabling ultrasensitive and specific mutation detection through integrated fluorescence and visual readouts. The system combines restriction-assisted mutant enrichment with cyclic CRISPR signal amplification. Genomic DNA is selectively digested with MscI to eliminate wild-type alleles, followed by T7 promoter–mediated PCR amplification and in vitro transcription. The resulting RNA activates Cas13a-crRNA complexes, initiating both direct reporter cleavage and dumbbell-triggered cascade amplification (DTCA) -mediated secondary signal enhancement. Under optimized conditions, the fluorescence mode achieved a variant allele frequency (VAF) sensitivity of 0.01%, with an estimated genomic DNA detection limit of ~ 3.6 fM in the integrated workflow and an RNA detection limit of ~ 2.16 pM. By replacing the fluorescent reporter with a FAM–biotin probe, the visual mode via lateral flow strips was realized with a VAF sensitivity of 0.01%. Clinical validation demonstrated complete concordance with next-generation sequencing (NGS), accurately classifying as high-, low-, and negative mutation samples. By integrating selective allele enrichment, cyclic amplification, and dual-mode readout, CIRCLE-F/V represents a sensitive, versatile, and clinically adaptable platform for rapid EGFR genotyping and early NSCLC screening.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, T. Z. E. (2026). CIRCLE-F/V: a dual-mode CRISPR-Cas13a cascade biosensor for ultrasensitive and visual detection of low-abundance EGFR mutations. https://doi.org/10.1186/s13036-026-00675-4

MLA

al, Tao Zhu et. "CIRCLE-F/V: a dual-mode CRISPR-Cas13a cascade biosensor for ultrasensitive and visual detection of low-abundance EGFR mutations." 2026. https://doi.org/10.1186/s13036-026-00675-4.

Chicago

al, Tao Zhu et. 2026. "CIRCLE-F/V: a dual-mode CRISPR-Cas13a cascade biosensor for ultrasensitive and visual detection of low-abundance EGFR mutations.". https://doi.org/10.1186/s13036-026-00675-4.

Harvard

al, T. Z. E. 2026, CIRCLE-F/V: a dual-mode CRISPR-Cas13a cascade biosensor for ultrasensitive and visual detection of low-abundance EGFR mutations, BMC, available at: https://doi.org/10.1186/s13036-026-00675-4 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
CIRCLE-F/V: a dual-mode CRISPR-Cas13a cascade biosensor for ultrasensitive and visual detection of low-abundance EGFR mutations
Author / contributors
Tao Zhu et al
Publisher
BMC
Publication year
2026
ISSN
1754-1611
ISSN
1754-1611
Language
English

Subjects

Explore related resources through these subjects.

Copied