Back to results
Bibliographic record · Consultation and access
Artículo

Impact of scanning errors on the trueness of digital implant impressions

Ragai-Edward Matta et al · SpringerOpen · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Purpose In dentistry, digital technologies have become firmly established in the field of oral implantology. The trueness of impressions taken using intraoral scanners as part of the digital workflow has a direct influence on the accuracy of fit of the subsequent restoration. Therefore, this in-vitro study investigates the influence of possible scanning errors on the trueness of digital implant impressions. Methods A standardized titanium model of a maxillary alveolar ridge with three bone-level implants was digitized with two different scan body systems (Medentika and NT-Training) using an industrial high-precision scanner to generate the virtual reference models. Subsequently, three different modifications, including two different gingival heights and artificially created defects, were each digitized 15 times using two different intraoral scanners (Primescan and Trios 4) with both scan body systems. The digitized scan bodies were then matched with the scan body analogs in the Exocad software to generate the virtual working models. Trueness was examined by superimposing the virtual working models with the corresponding virtual reference model. Results All scanning errors evaluated resulted in significantly higher deviations. Across all groups, the trueness decreased with increasing gingival height. The best results (30 ± 15 μm) were attained when scanning at the lower gingival height. The largest discrepancy (178 ± 63 μm) was found when impressions of the higher gingival height were taken. Conclusion In the process of taking digital implant impressions, it is essential to maximize the exposure of the scan bodies. Furthermore, it is imperative to minimize defects in order to achieve optimal outcomes. Graphical abstract

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, R. E. M. E. (2026). Impact of scanning errors on the trueness of digital implant impressions. https://doi.org/10.1186/s40729-026-00684-4

MLA

al, Ragai-Edward Matta et. "Impact of scanning errors on the trueness of digital implant impressions." 2026. https://doi.org/10.1186/s40729-026-00684-4.

Chicago

al, Ragai-Edward Matta et. 2026. "Impact of scanning errors on the trueness of digital implant impressions.". https://doi.org/10.1186/s40729-026-00684-4.

Harvard

al, R. E. M. E. 2026, Impact of scanning errors on the trueness of digital implant impressions, SpringerOpen, available at: https://doi.org/10.1186/s40729-026-00684-4 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Impact of scanning errors on the trueness of digital implant impressions
Author / contributors
Ragai-Edward Matta et al
Publisher
SpringerOpen
Publication year
2026
ISSN
2198-4034
ISSN
2198-4034
Language
English

Subjects

Explore related resources through these subjects.

Copied