Back to results
Bibliographic record · Consultation and access
Artículo

Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model

Anna M. Hunkemöller et al · SpringerOpen · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract Objective Photon-counting CT (PCCT) combines improved dose efficiency with spectral imaging, enabling dynamic functional imaging at chest CT dose levels. Dual energy CT typically uses perfused blood volume (PBV) as a static perfusion surrogate. This study compared low-dose dynamic PCCT compared with reference-dose PCCT and static PBV imaging. Materials and methods Six minipigs with left lung transplants underwent dynamic perfusion imaging using PCCT at reference and low-dose settings, along with a static PBV scan. Perfusion metrics—Blood Flow Deconvolution (BFD), Mean Transit Time Deconvolution (MTTD), Flow Extraction Product (FEP), and Time to Start Deconvolution (TTSD)—were normalized and analyzed across six lung regions using Kruskal-Wallis tests and Bland-Altman analysis. Results Low-dose and reference-dose dynamic PCCT showed strong agreement across perfusion parameters (BVP bias: 0.03; BVD bias: 0.04), with no significant differences in BVP (p = 0.995) or BVD (p = 0.374). Kinetic metrics were stable across dose levels (all p > 0.2). While low-dose imaging showed slightly greater perfusion heterogeneity, BVP remained robust. Static PBV differed significantly from dynamic BVP (reference dose: p < 0.001; low-dose: p = 0.04). Left-right perfusion differences were detected in two animals by all methods. Estimated doses were 2.37 mSv (reference-dose) and 1.36 mSv (low-dose), comparable to chest CT (1.49 mSv) and below conventional CT perfusion (3–10 mSv). Conclusion Dynamic PCCT enables quantitative lung perfusion imaging at radiation doses comparable to standard chest CT. Low-dose dynamic PCCT shows strong agreement with reference-dose acquisitions, while dynamic parameters reveal functional differences not captured by static PBV imaging. Relevance statement Dynamic low-dose photon-counting computed tomography enables lung perfusion quantification at radiation doses comparable to standard chest CT, facilitating dose-efficient functional imaging in pulmonary disease. Key Points Low-dose PCCT (~ 1.36 mSv) is feasible, comparable to single chest CT (1.49 mSv). Strong agreement was seen between low- and reference-dose PCCT (BVP bias 0.03; BVD bias 0.04). Kinetic perfusion metrics remained stable across dose levels (all p > 0.2). Graphical Abstract

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, A. M. H. E. (2026). Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model. https://doi.org/10.1186/s41747-026-00723-0

MLA

al, Anna M. Hunkemöller et. "Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model." 2026. https://doi.org/10.1186/s41747-026-00723-0.

Chicago

al, Anna M. Hunkemöller et. 2026. "Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model.". https://doi.org/10.1186/s41747-026-00723-0.

Harvard

al, A. M. H. E. 2026, Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model, SpringerOpen, available at: https://doi.org/10.1186/s41747-026-00723-0 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model
Author / contributors
Anna M. Hunkemöller et al
Publisher
SpringerOpen
Publication year
2026
ISSN
2509-9280
ISSN
2509-9280
Language
English

Subjects

Explore related resources through these subjects.

Copied