Back to results
Bibliographic record · Consultation and access
Artículo

Enhanced power quality in grid-connected wind energy systems using PI-controlled with doubly fed induction generator optimized by hybrid differential evolution and grey wolf algorithm

R. F. Abdelgoui et al · National Technical University "Kharkiv Polytechnic Institute" · 2026

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Introduction. Nowadays, the most widely used wind energy conversion system in wind farms is based on a doubly fed induction generator (DFIG); it has a large speed range and can function in multiple modes. Problem. Harmonic distortion in wind energy conversion system can degrade output waveform quality, reduce power conversion efficiency. Goal. This study investigates the dynamic performance of a wind energy conversion system comprising a grid-connected load, a 13-level hybrid multilevel converter and a doubly fed induction generator (DFIG), using a PI controller. The study aims to evaluate the dynamic performance and power quality of wind energy conversion systems, and to develop a novel hybrid metaheuristic method combining differential evolution (DE) and grey wolf optimization (GWO)-based selective harmonic elimination pulse-width modulation (SHEPWM) control strategies. This method reduces total harmonic distortion (THD) and ensures compliance with IEEE 519 standards, while increasing the power transferred to the grid. Methodology. The system, which includes a grid-connected load, a 13-level converter, and a DFIG, is modeled and simulated in MATLAB/Simulink under steady-state wind conditions. Vector control via stator flow orientation was used to modify the energy quality provided by the DFIG, making the system comparable to the DC machine. Our approach was to use a PI controller in order to directly control the active and reactive DFIG power through multi-level converter then a hybrid metaheuristic algorithm combining DE and GWO is implemented to solve the SHEPWM nonlinear transcendental equations. The proposed algorithm is evaluated based on its ability to suppress lower-order harmonics and improve THD performance, these converters increase the power transmitted to the power grid by reducing harmonic content of the output voltages. Results. By using the DE-GWO hybrid method and a PI controller, lower-order harmonics were effectively removed and THD was reduced to meet IEEE 519 standards. Simulations showed an improvement in output wave quality and better energy conversion efficiency compared to conventional optimization methods. Scientific novelty of the proposed work lies in the fact that the study introduces a novel DE-GWO hybrid optimization method for PWM (SHEPWM) in 13-level hybrid multilevel converter applied to wind energy systems. Practical value. The novel method demonstrates that constant high performance in wind energy systems may be achieved by combining intelligent optimization algorithms with complex multilevel converter designs This means it can be effectively integrated into contemporary wind farms where meeting grid standards, adjusting to varying sizes, and ensuring long-term reliability are crucial. References 26, table 1, figures 19.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, R. F. A. E. (2026). Enhanced power quality in grid-connected wind energy systems using PI-controlled with doubly fed induction generator optimized by hybrid differential evolution and grey wolf algorithm. https://doi.org/10.20998/2074-272X.2026.3.05

MLA

al, R. F. Abdelgoui et. "Enhanced power quality in grid-connected wind energy systems using PI-controlled with doubly fed induction generator optimized by hybrid differential evolution and grey wolf algorithm." 2026. https://doi.org/10.20998/2074-272X.2026.3.05.

Chicago

al, R. F. Abdelgoui et. 2026. "Enhanced power quality in grid-connected wind energy systems using PI-controlled with doubly fed induction generator optimized by hybrid differential evolution and grey wolf algorithm.". https://doi.org/10.20998/2074-272X.2026.3.05.

Harvard

al, R. F. A. E. 2026, Enhanced power quality in grid-connected wind energy systems using PI-controlled with doubly fed induction generator optimized by hybrid differential evolution and grey wolf algorithm, National Technical University "Kharkiv Polytechnic Institute", available at: https://doi.org/10.20998/2074-272X.2026.3.05 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Enhanced power quality in grid-connected wind energy systems using PI-controlled with doubly fed induction generator optimized by hybrid differential evolution and grey wolf algorithm
Author / contributors
R. F. Abdelgoui et al
Publisher
National Technical University "Kharkiv Polytechnic Institute"
Publication year
2026
ISSN
2074-272X
ISSN
2074-272X
Language
English

Subjects

Explore related resources through these subjects.