Back to results
Bibliographic record · Consultation and access
Artículo

Design and Simulation of Flow Field for Bone Tissue Engineering Scaffold Based on Triply Periodic Minimal Surface

Zhen Wang et al · KeAi Communications Co., Ltd · 2019

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

Abstract A novel method was proposed to design the structure of a bone tissue engineering scaffold based on triply periodic minimal surface. In this method, reverse engineering software was used to reconstruct the surface from point cloud data. This method overcomes the limitations of commercially available software packages that prevent them from generating models with complex surfaces used for bone tissue engineering scaffolds. Additionally, the fluid field of the scaffolds was simulated through a numerical method based on finite volume and the cell proliferation performance was evaluated via an in vitro experiment. The cell proliferation and the mass flow evaluated in a bioreactor further verified the flow field simulated using computational fluid dynamics. The result of this study illustrates that the pressure value drops rapidly from 0.103 Pa to 0.011 Pa in the y-axis direction and the mass flow is unevenly distributed in the outlets. The mass flow in the side outlets is observed to be approximately 24.3 times higher than that in the bottom outlets in the range 6.13 × 10−8 kg/s to 1.49 × 10−6 kg/s. Moreover, the mass flow in the bottom outlets decreases from the center to the edge, whereas the mass flow in the side outlets decreases from the top to the bottom. Importantly, although the mean value of wall shear stress is significantly more than 0.05 Pa, there is still a large area with a suitable shear stress below 0.05 Pa where most cells can proliferate well. The result shows that the inlet velocity 0.0075 m/s is suitable for cell proliferation in the scaffold. This study provides an insight into the design, analysis, and in vitro experiment of a bone tissue engineering scaffold.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, Z. W. E. (2019). Design and Simulation of Flow Field for Bone Tissue Engineering Scaffold Based on Triply Periodic Minimal Surface. https://doi.org/10.1186/s10033-019-0329-7

MLA

al, Zhen Wang et. "Design and Simulation of Flow Field for Bone Tissue Engineering Scaffold Based on Triply Periodic Minimal Surface." 2019. https://doi.org/10.1186/s10033-019-0329-7.

Chicago

al, Zhen Wang et. 2019. "Design and Simulation of Flow Field for Bone Tissue Engineering Scaffold Based on Triply Periodic Minimal Surface.". https://doi.org/10.1186/s10033-019-0329-7.

Harvard

al, Z. W. E. 2019, Design and Simulation of Flow Field for Bone Tissue Engineering Scaffold Based on Triply Periodic Minimal Surface, KeAi Communications Co, Ltd, available at: https://doi.org/10.1186/s10033-019-0329-7 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Design and Simulation of Flow Field for Bone Tissue Engineering Scaffold Based on Triply Periodic Minimal Surface
Author / contributors
Zhen Wang et al
Publisher
KeAi Communications Co., Ltd
Publication year
2019
ISSN
1000-9345
ISSN
1000-9345
Language
English

Subjects

Explore related resources through these subjects.

Copied