Back to results
Bibliographic record · Consultation and access
Artículo

Evaluation of water absorption and solubility of digitally and conventionally produced temporary fixed materials

Sahin Zeynep et al · Balkan Stomatological Society · 2024

Open-access full text
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open-access full text

Texto completo identificado como acceso abierto.
Open text

Summary

Descripción general del contenido del recurso.

Background/Aim: The study aims to evaluate water sorption and solubility of conventional and digitally produced temporary fixed materials. Material and Methods: A total of 40 disc-shaped specimens were prepared from two conventionally produced temporary fixed materials: bis-acrylic composite resin (Protemp 4-PT) and acrylic resin (Dentalon plus-DP) and two digitally produced [3D printing (MACK4D Temp-MT) and CAD/CAM milling (On Dent-OD)]. The prepared disks were dried in a desiccator until they reached a constant mass. They were then kept in distilled water at 37°C for 1 week and weighed. The weights of the specimens, which were again subjected to conditions similar the initial drying procedure, were measured. Water absorption and solubility values were calculated by formula. The data obtained were analyzed using 1-way analysis of variance (ANOVA) and the Tamhane or Tukey post hoc test (a=.05). Results: Water absorption values of the PT group (24.16±8.1 µg/mm 3) were statistically higher than all other groups (p= 0.001). However, there was no significant difference in the pairwise comparisons of OD, MT, and DP groups (p>0.05). When the water solubility values were analyzed, DP group (0.49±2.01 µg/mm 3) showed no significant difference with the PT group (1.69±2.2 µg/mm 3) (p=0.402), while they were higher than OD (-3.96±0.84 µg/mm 3) and MT (-10.29±1.37 µg/ mm 3) groups. In addition, a significant difference was observed in the water solubility values of CAD/CAM-3D groups (p<0.05). Conclusions: All of test groups were found to be within the values recommended by ISO standards. It can be inferred that the PT material may cause the most staining.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. Z. E. (2024). Evaluation of water absorption and solubility of digitally and conventionally produced temporary fixed materials. https://doi.org/10.5937/bjdm2401033S

MLA

al, Sahin Zeynep et. "Evaluation of water absorption and solubility of digitally and conventionally produced temporary fixed materials." 2024. https://doi.org/10.5937/bjdm2401033S.

Chicago

al, Sahin Zeynep et. 2024. "Evaluation of water absorption and solubility of digitally and conventionally produced temporary fixed materials.". https://doi.org/10.5937/bjdm2401033S.

Harvard

al, S. Z. E. 2024, Evaluation of water absorption and solubility of digitally and conventionally produced temporary fixed materials, Balkan Stomatological Society, available at: https://doi.org/10.5937/bjdm2401033S [Accessed 5 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Evaluation of water absorption and solubility of digitally and conventionally produced temporary fixed materials
Author / contributors
Sahin Zeynep et al
Publisher
Balkan Stomatological Society
Publication year
2024
ISSN
2335-0245
ISSN
2335-0245
Language
English

Subjects

Explore related resources through these subjects.

Copied