<span>The article describes a method for measuring the concentration of glucose in human blood by non-invasive method using near-infrared optical technology. In medical practice, glucose concentration in the blood in most cases is measured by invasive methods involving the collection of blood from the finger or vein, while non-invasive devices for determining the level of glucose preserve the operational measurement of blood-borne levels. Invasive methods are expensive and painful. Frequent piercing of fingers causes corns on the skin, and also increases the risk of spreading infectious diseases. Thus, the development of a system of non-invasive measurement of glucose in the blood will be useful for patients with diabetes mellitus. Non-invasive way of measuring glucose levels in human blood is based on the use of pain-free optical technology based on near-infrared (BIC) radiation. The proposed system consists of emitters of signals with a wavelength of 940 nm. These optical signals are sent through the earlobe, and the rays passing through it are fixed by a phototransistor located on another part of the device. The concentration of glucose in the blood is determined by analyzing the intensity variation obtained after passing the signal. The results obtained from the developed system show the feasibility of using a non-invasive BIC method for monitoring blood glucose levels. The accuracy of the measurements of the proposed system can be improved by integrating its sensitive and emitting elements based on the SOI of the CMOS structures. </span><strong>Keywords:</strong><span> blood glucose, diabetes, near-infrared, noninvasive method SOI CMOS-structure.</span>

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. K. E. (2018). Sensory Elements and Devices Operational Diagnostic Blood Glucose. https://doi.org/10.15330/pcss.18.4.471

MLA

al, M.V. Kotyk et. "Sensory Elements and Devices Operational Diagnostic Blood Glucose." 2018. https://doi.org/10.15330/pcss.18.4.471.

Chicago

al, M.V. Kotyk et. 2018. "Sensory Elements and Devices Operational Diagnostic Blood Glucose.". https://doi.org/10.15330/pcss.18.4.471.

Harvard

al, M. K. E. 2018, Sensory Elements and Devices Operational Diagnostic Blood Glucose, Vasyl Stefanyk Carpathian National University, available at: https://doi.org/10.15330/pcss.18.4.471 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Sensory Elements and Devices Operational Diagnostic Blood Glucose
Author / contributors
M.V. Kotyk et al
Publisher
Vasyl Stefanyk Carpathian National University
Publication year
2018
ISSN
1729-4428
ISSN
1729-4428
Language
English
Copied