Protection System Coordination On 20 kV Distribution Network In Makassar City

Firdaus Firdaus et al · Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun · 2023

Open-access full text
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open-access full text

Texto completo identificado como acceso abierto.
Open text

Summary

Descripción general del contenido del recurso.

This study is a quantitative study that aims to a) describe the coordination of protection systems under abnormal conditions in the distribution network and b) to determine the selectiveity of protection systems in isolating equipment in abnormal conditions of distribution networks. Data setting existing rele protection system obtained in PT. PLN (Persero) UP2D Makassar, the data is then processed, simulated, and analyzed using the ETAP 19.0.1 program. The series analyzed in this study is the distribution network PLN ULP Karebosi Paotere refiner with a channel length of 8,234 km, where sktm channel 0.844 km and SUTM 7,390 km, consisting of 33 distribution substations. The results showed that the flow of short circuit disruption on Hatta buses was: 3-Phase by 3,887 kA, Line-to-Ground by 3,550 kA, Line-to-Line by 3,357 kA, and Line-to-Line-to-Ground by 3,831 kA. To achieve reliability and coordination of protection system equipment resetting rele on recloser Sabutung Set OCR 250 kA, TMS-TD OCR 0.08 s, moment OCR 3x, Sect. Paotere bridge OCR 200 kA, TMS-TD OCR 0.07 s, moment OCR Block, Sect. Hatta OCR 180 kA, TMS-TD OCR 0.05 s, moment OCR Block.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, F. F. E. (2023). Protection System Coordination On 20 kV Distribution Network In Makassar City. https://doi.org/10.33387/protk.v10i2.4204

MLA

al, Firdaus Firdaus et. "Protection System Coordination On 20 kV Distribution Network In Makassar City." 2023. https://doi.org/10.33387/protk.v10i2.4204.

Chicago

al, Firdaus Firdaus et. 2023. "Protection System Coordination On 20 kV Distribution Network In Makassar City.". https://doi.org/10.33387/protk.v10i2.4204.

Harvard

al, F. F. E. 2023, Protection System Coordination On 20 kV Distribution Network In Makassar City, Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun, available at: https://doi.org/10.33387/protk.v10i2.4204 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Protection System Coordination On 20 kV Distribution Network In Makassar City
Author / contributors
Firdaus Firdaus et al
Publisher
Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun
Publication year
2023
ISSN
2354-8924
ISSN
2354-8924
Language
English
Copied