Back to results
Bibliographic record · Consultation and access
Artículo

Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs

Marleen Brans et al · Oxford University Press · 2023

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Background Stability of serum symmetric dimethylarginine (sSDMA) during short‐ and long‐term storage has not been assessed for the immunoassay of the Point‐of‐Care IDEXX Catalyst DX (POC) analyzer and the Enzyme Multiplied Immunoassay Technique of IDEXX commercial laboratory (CL). Also, the agreement between both analyzers is questioned. Objectives To determine (a) the effect of storage time and temperature on sSDMA measured by POC and CL; (b) the agreement between sSDMA measured by POC and CL; and (c) the imprecision of the POC. Animals Serum of cats (n = 17) and dogs (n = 18) with a range of SDMA concentrations (6 to >100 μg/dL). Methods Based on an equivalence trial with predefined equivalence range (−3.0 to +3.0 μg/dL) and using T0 as baseline, stability was evaluated after 24 hours at 22°C and 4°C (POC); after 7 days at 4°C (POC and CL) and after 10 and 24 months at −24°C and −80°C (CL). Bland‐Altman plots enabled method comparison. Imprecision of the POC was assessed by duplicate sSDMA measurements at T0. Results The POC analyzer produced equivalent sSDMA measurements if samples were stored for 24 hours at 4°C (95% confidence interval [CI]: −2.5‐2.0 μg/dL), but not when stored for 24 hours at room temperature (RT; 95% CI: −4.1 to 0.5 μg/dL) or after 7 days at 4°C (95% CI: −3.6‐1.0 μg/dL). The CL analyzer was less affected by preanalytical variation with clinically similar results obtained when samples were stored for 7 days at 4°C (95% CI: −2.2 to 2.4 μg/dL) and for at least 24 months at −24°C (95% CI: −1.7 to 2.9 μg/dL) and −80°C (95% CI: −1.5 to 3 μg/dL). A relevant mean difference of −2.3 μg/dL between both analyzers was found. Duplicate POC measurements were equivalent (95% CI: −2.6 to 2.0 μg/dL). Conclusions Delayed analysis may significantly change sSDMA depending on storage and measurement conditions. Interchangeable use of assays should be done with caution because analytical variation could be interpreted as clinically relevant change.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. B. E. (2023). Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs. https://doi.org/10.1111/jvim.16811

MLA

al, Marleen Brans et. "Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs." 2023. https://doi.org/10.1111/jvim.16811.

Chicago

al, Marleen Brans et. 2023. "Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs.". https://doi.org/10.1111/jvim.16811.

Harvard

al, M. B. E. 2023, Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs, Oxford University Press, available at: https://doi.org/10.1111/jvim.16811 [Accessed 10 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Effect of storage temperature and time on measurement of serum symmetric dimethylarginine concentration using point‐of‐care and commercial laboratory analyzers in cats and dogs
Author / contributors
Marleen Brans et al
Publisher
Oxford University Press
Publication year
2023
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied