Back to results
Bibliographic record · Consultation and access
Artículo

Highly sensitive microfiber ultrasound sensor for photoacoustic imaging

Perry Ping Shum et al · Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China · 2023

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

An ultrasound wave is a kind of acoustic signal with a frequency greater than 20 kHz, which is widely used in diverse fields such as medical imaging diagnosis, nondestructive testing and resource exploration. A variety of ultrasound sensors have been developed for ultrasound detection. Particularly for photoacoustic imaging, specialized ultrasound sensors with high sensitivity, small size, and broad bandwidth are needed. However, achieving such sensor performance still poses a great challenge to the current state-of-the-art in ultrasound sensor technology. A recent work published in Opto-Electronic Advances (DOI: 10.29026/oea.2022.200076) proposes a microfiber-based ultrasound sensor that breaks the limitations of existing ultrasound sensors. Benefiting from the large evanescent field characteristic of microfiber, combined with the coherent detection technology, the proposed sensor realized highly sensitive ultrasound detection and demonstrated excellent performance in high-resolution photoacoustic imaging. The highly sensitive and miniaturized microfiber ultrasound sensor provides a competitive alternative for various applications, such as endoscopic photoacoustic imaging of the intestinal tract and blood vessels in animals.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, P. P. S. E. (2023). Highly sensitive microfiber ultrasound sensor for photoacoustic imaging. https://doi.org/10.29026/oea.2023.230065

MLA

al, Perry Ping Shum et. "Highly sensitive microfiber ultrasound sensor for photoacoustic imaging." 2023. https://doi.org/10.29026/oea.2023.230065.

Chicago

al, Perry Ping Shum et. 2023. "Highly sensitive microfiber ultrasound sensor for photoacoustic imaging.". https://doi.org/10.29026/oea.2023.230065.

Harvard

al, P. P. S. E. 2023, Highly sensitive microfiber ultrasound sensor for photoacoustic imaging, Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China, available at: https://doi.org/10.29026/oea.2023.230065 [Accessed 7 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Highly sensitive microfiber ultrasound sensor for photoacoustic imaging
Author / contributors
Perry Ping Shum et al
Publisher
Editorial Office of Opto-Electronic Journals Group, Institute of Optics and Electronics, CAS, China
Publication year
2023
ISSN
2096-4579
ISSN
2096-4579
Language
English