Back to results
Bibliographic record · Consultation and access
Artículo

Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies

Marília Zicker Hanan et al · Federação Brasileira das Sociedades de Ginecologia e Obstetrícia · 2008

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A FEBRASGO e o Novo Ano

This serial publication contains 195 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

OBJETIVO: verificar a correlação entre as medidas ultra-sonográficas do coração fetal e o deficit de hemoglobina em fetos de gestantes aloimunizadas. MÉTODOS: estudo transversal, no qual foram incluídos 60 fetos de 56 mulheres aloimunizadas, com idade gestacional entre 21 e 35 semanas. Foram realizados 139 procedimentos. Antes da cordocentese para a coleta de sangue fetal, as medidas cardíacas e o comprimento do fêmur (CF) foram avaliados pela ultra-sonografia. O diâmetro biventricular externo (DBVE) foi obtido no final da diástole, com o cursor modo-M perpendicular ao septo interventricular, nas válvulas atrioventriculares, medindo-se a distância entre as partes externas dos epicárdios. A medida do diâmetro atrioventricular (DAV) foi obtida posicionando-se o mesmo cursor ao longo do septo interventricular, avaliando-se a distância entre a base e o ápice do coração. O CF foi determinado do trocanter maior à metáfise distal. Foi calculada a circunferência cardíaca (CC). Para ajustar as medidas cardíacas à idade gestacional, dividiu-se cada uma dessas medidas pela medida do CF. A concentração de hemoglobina foi determinada por espectrofotometria no sistema Hemocue®. O deficit de hemoglobina foi calculado baseado na curva de normalidade de Nicolaides. RESULTADOS: observaram-se correlações diretas e significativas entre as medidas cardíacas avaliadas e o deficit de hemoglobina. Para a predição das anemias moderada e grave, a sensibilidade e a especificidade encontradas foram, respectivamente, de 71,7 e 66,3% para a razão DBVE e CF; 65,8 e 62,4% para a DAV e CF e 73,7 e 60,4% para a CC e CF. CONCLUSÕES: nos fetos de gestantes aloimunizadas, as medidas cardíacas ultra-sonográficas avaliadas correlacionam-se diretamente com o deficit de hemoglobina.<br>PURPOSE: to verify the correlation between ultrasonography heart measures and hemoglobin deficit in fetuses of alloimmunized pregnant women. METHODS: a transversal study, including 60 fetuses, with 21 to 35 weeks of gestational age, from 56 isoimmunized pregnant women. A number of 139 procedures were performed. Before cordocentesis for the collection of fetal blood, cardiac measures and femur length (FL) were assessed by ultrasonography. The external biventricular diameter (EBVD) was obtained by measuring the distance between the epicardic external parts at the end of the diastole, with the M-mode cursor perpendicular to the interventricular septum, in the atrioventricular valves. The measure of the atrioventricular diameter (AVD) was obtained by positioning the same cursor along the interventricular septum, evaluating the distance between the heart basis and apex. The FL was determined from the trochanter major to the distal metaphysis. The cardiac circumference (CC) was also calculated. To adjust the cardiac measure to the gestational age, each of these measures were divided by the FL measure. Hemoglobin concentration has been determined by spectrophotometry with the Hemocue® system. Hemoglobin deficit calculation was based in the Nicolaides's normality curve. RESULTS: direct and significant correlations were observed between the cardiac measures evaluated and the hemoglobin deficit. To predict moderate and severe anemia, the sensitivity and specificity found were 71.7 and 66.3% for EBVD and FL, 65.8 and 62.4% for AVD and FL, and 73.7 and 60.4% for CC and FL, respectively. CONCLUSIONS: ultrasonography cardiac measures assessed from fetuses of isoimmunized pregnant women correlate directly with hemoglobin deficit.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, M. Z. H. E. (2008). Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies. https://doi.org/10.1590/S0100-72032008000700004

MLA

al, Marília Zicker Hanan et. "Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies." 2008. https://doi.org/10.1590/S0100-72032008000700004.

Chicago

al, Marília Zicker Hanan et. 2008. "Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies.". https://doi.org/10.1590/S0100-72032008000700004.

Harvard

al, M. Z. H. E. 2008, Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies, Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, available at: https://doi.org/10.1590/S0100-72032008000700004 [Accessed 6 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
Correlação entre medidas ultra-sonográficas do coração e o deficit de hemoglobina em fetos de gestantes aloimunizadas Correlation between echographic cardiac measurements and hemoglobin deficit in fetus of red cell alloimmunized pregnancies
Author / contributors
Marília Zicker Hanan et al
Publisher
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia
Publication year
2008
ISSN
0100-7203
ISSN
0100-7203
Language
English

Subjects

Explore related resources through these subjects.

Copied