Back to results
Bibliographic record · Consultation and access
Artículo

A novel placement method of a calibration‐free pH capsule for continuous wireless measurement of intragastric pH in horses

Evelyn Hodgson et al · Oxford University Press · 2025

Open access available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.
Serial publication

A de novo nonsense variant in the DMD gene associated with X‐linked dystrophin‐deficient muscular dystrophy in a cat

This serial publication contains 149 related contents.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open access available

Recurso identificado como acceso abierto, sin confirmar automáticamente si es texto completo directo.
Open resource

Summary

Descripción general del contenido del recurso.

Abstract Background Current methods to measure intragastric pH in horses have limitations. A wireless capsule has been designed for continuous esophageal pH monitoring in humans. Objectives To (1) determine the feasibility and describe the methodology of measuring intragastric pH wirelessly in horses; and (2) determine attachment duration of the capsules. Animals Eleven healthy adult horses. Methods Capsules were attached to squamous and glandular gastric mucosa under gastroscopic guidance, using suture loops and 1 to 4 hemostasis clips. pH was continuously recorded using a wireless recorder in both fed and fasted states. Gastroscopy was performed daily to assess capsule attachment and any mucosal damage. Data were analyzed using commercially available software. Values are reported as median (interquartile range). Results Capsules were successfully placed and data obtained in squamous (n = 11) and glandular (n = 7) regions. The overall duration of squamous capsule attachment was 27 hours (15‐32); 1 clip (n = 4) was 15 hours (11‐20), 2 clips (n = 2) was 20 hours (16‐23), 3 clips (n = 4) was 32 hours (30‐32), and 4 clips (n = 1) was 33 hours. The overall duration of glandular capsule attachment was 10 hours (8‐21); 1 clip (n = 2) was 11 hours (10‐13), 2 clips (n = 2) was 19 hours (14‐23), 3 clips (n = 2) was 7 hours (7‐8), and 4 clips (n = 1) was 158 hours. There was no substantial damage to the gastric mucosa as a consequence of attachment. Conclusions and Clinical Importance This novel technique enables the wireless measurement of intragastric pH in horses at known locations under fed and fasted conditions, providing a viable alternative for continuous monitoring in both research and clinical scenarios.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, E. H. E. (2025). A novel placement method of a calibration‐free pH capsule for continuous wireless measurement of intragastric pH in horses. https://doi.org/10.1111/jvim.17273

MLA

al, Evelyn Hodgson et. "A novel placement method of a calibration‐free pH capsule for continuous wireless measurement of intragastric pH in horses." 2025. https://doi.org/10.1111/jvim.17273.

Chicago

al, Evelyn Hodgson et. 2025. "A novel placement method of a calibration‐free pH capsule for continuous wireless measurement of intragastric pH in horses.". https://doi.org/10.1111/jvim.17273.

Harvard

al, E. H. E. 2025, A novel placement method of a calibration‐free pH capsule for continuous wireless measurement of intragastric pH in horses, Oxford University Press, available at: https://doi.org/10.1111/jvim.17273 [Accessed 9 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
A novel placement method of a calibration‐free pH capsule for continuous wireless measurement of intragastric pH in horses
Author / contributors
Evelyn Hodgson et al
Publisher
Oxford University Press
Publication year
2025
ISSN
0891-6640
ISSN
0891-6640
Language
English

Subjects

Explore related resources through these subjects.

Copied