EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION

Taryo Taryo et al · Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun · 2025

Open-access full text
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Open-access full text

Texto completo identificado como acceso abierto.
Open text

Summary

Descripción general del contenido del recurso.

Grounding serves a crucial role in the field lightning protection, electric power, and electric power communications networks. The grounding system's purpose is to guide the flow of electrical charges to the ground mass as rapidly as feasible. The goal of this study is to analyze the grounding system utilized to ensure the continuity of electrical energy production and delivery. In this study, quantitative methods are used to calculate lightning parameters, substation protection by earthing wires and protection towers, earthing system, mesh voltages, touch voltages and step voltages. According to IEEE 80-2013 (latest revision) standards, an ideal earthing application should have a resistance value of 1Ω. The results of the analysis and calculation of the grounding system using the grid grounding type obtained a value of 0.28276 Ω (1Ω), and mesh voltage 0,851314 kV. The protection system which consists of a 103.47288 M ground wire and a 55.27325 M protection tower, is capable of protecting the substation from lightning strikes with a peak current of 51.32913 kA. The touch voltage for humans weighing 50kg and 70kg is 133.39304 V and 180.54060 V, and the step voltage results in 185.5770 V and 251.1690 V. When the grounding current at touch and step voltages is considered, the values become 442.87730 kV and 616.17712 kV. Both exceed the allowed levels of 626 and 2,216 V.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, T. T. E. (2025). EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION. https://doi.org/10.33387/protk.v12i1.8319

MLA

al, Taryo Taryo et. "EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION." 2025. https://doi.org/10.33387/protk.v12i1.8319.

Chicago

al, Taryo Taryo et. 2025. "EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION.". https://doi.org/10.33387/protk.v12i1.8319.

Harvard

al, T. T. E. 2025, EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION, Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun, available at: https://doi.org/10.33387/protk.v12i1.8319 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION
Author / contributors
Taryo Taryo et al
Publisher
Department of Electrical Engineering, Faculty of Engineering, Universitas Khairun
Publication year
2025
ISSN
2354-8924
ISSN
2354-8924
Language
English

Subjects

Explore related resources through these subjects.

Copied