Back to results
Bibliographic record · Consultation and access
Artículo

A “plasmonic cuvette”: dye chemistry coupled to plasmonic interferometry for glucose sensing

Siu Vince S. et al · Wiley · 2014

Supplementary material available
Quick overview. Review the resource’s basic details, then access the content using the main button. This page shows only the information needed to identify, cite, and open the work.

Resource access

Open the content from the main option or choose another available source.

DOAJ DOAJ Articles
Entrar por DOAJ
Main access

Supplementary material available

El enlace apunta a material asociado, anexos, tablas, datos o página complementaria. No se marca como libro/texto completo.
Open material

Summary

Descripción general del contenido del recurso.

A non-invasive method for the detection of glucose is sought by millions of diabetic patients to improve personal management of blood glucose over a lifetime. In this work, the synergistic advantage of combining plasmonic interferometry with an enzyme-driven dye assay yields an optical sensor capable of detecting glucose in saliva with high sensitivity and selectivity. The sensor, coined a “plasmonic cuvette,” is built around a nano-scale groove-slit-groove (GSG) plasmonic interferometer coupled to an Amplex–red/Glucose–oxidase/Glucose (AR/GOx/Glucose) assay. The proposed device is highly sensitive, with a measured intensity change of 1.7×105%/m (i.e., one order of magnitude more sensitive than without assay) and highly specific for glucose sensing in picoliter volumes, across the physiological range of glucose concentrations found in human saliva (20–240 μm). Real-time glucose monitoring in saliva is achieved by performing a detailed study of the underlying enzyme-driven reactions to determine and tune the effective rate constants in order to reduce the overall assay reaction time to ∼2 min. The results reported suggest that by opportunely choosing the appropriate dye chemistry, a plasmonic cuvette can be turned into a general, real-time sensing scheme for detection of any molecular target, with high sensitivity and selectivity, within extremely low volumes of biological fluid (down to femtoliters). Hereby, we present the results on glucose detection in artificial saliva as a notable and clinically relevant case study.

How to cite

Elegí el formato que necesitás y copiá la referencia al portapapeles.

APA 7

al, S. V. S. E. (2014). A “plasmonic cuvette”: dye chemistry coupled to plasmonic interferometry for glucose sensing. https://doi.org/10.1515/nanoph-2013-0057

MLA

al, Siu Vince S. et. "A “plasmonic cuvette”: dye chemistry coupled to plasmonic interferometry for glucose sensing." 2014. https://doi.org/10.1515/nanoph-2013-0057.

Chicago

al, Siu Vince S. et. 2014. "A “plasmonic cuvette”: dye chemistry coupled to plasmonic interferometry for glucose sensing.". https://doi.org/10.1515/nanoph-2013-0057.

Harvard

al, S. V. S. E. 2014, A “plasmonic cuvette”: dye chemistry coupled to plasmonic interferometry for glucose sensing, Wiley, available at: https://doi.org/10.1515/nanoph-2013-0057 [Accessed 8 Aug. 2026].

Share and print

Save the record, copy its permanent link, or print it as a PDF.

Export reference

You can export the record in common formats for use in a reference manager.

Resource details

Bibliographic information to help confirm that this is the correct material.

Title
A “plasmonic cuvette”: dye chemistry coupled to plasmonic interferometry for glucose sensing
Author / contributors
Siu Vince S. et al
Publisher
Wiley
Publication year
2014
ISSN
2192-8606
ISSN
2192-8606
Language
English

Subjects

Explore related resources through these subjects.

Copied